Retention — calculations

Retention: 10 ac subdivision — Retention on Subdivision (stand-alone: this catchment's runoff only)
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

How this treatment's values are worked out: the equations, then the values they are worked with (v1's Equations button). A change on the Entry or Sizing tab shows here at once.

Equations

Treatment Depth (in) = Retention Volume (ac-ft) / Contributing Area (ac) x 12

Notes

Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.

The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.

N and P removal are equal to the hydraulic capture efficiency.

Values

VariableCurrent value
Retention Volume1.000 ac-ft
Contributing Area10.000 ac
Watershed Area10.000 ac
Non-DCIA Curve Number75
DCIA Percent25 %
Rainfall ZoneFlorida Zone 2
Treatment Depth1.200 in
Hydraulic Capture88.4 %
Treatment Rate(no media mix)
N removal88.4 %
P removal88.4 %