Compare routings

Surface discharge filters routed in series
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

Each routing calculated with v1's engine and its own method. N is nitrogen, P phosphorus. ★ marks the lowest load to the outlet. "Meets" uses v1's rule: the removal provided against the greater of the type of analysis's percentage and the post = pre removal, where the type uses it. The life-cycle cost adds up the costs entered on the Cost tabs of the treatments each routing uses.

Routings

RoutingMethodN to outlet (kg/yr)N removed / needed (%)P to outlet (kg/yr)P removed / needed (%)MeetsRunoff out (ac-ft/yr)
Routing 1Strand (v1's)101.9450.79 / 70.416.1268.41 / 89.8No: N short (50.8 of 70.4 %); P short (68.4 of 89.8 %)0.00
Routing 2Strand (v1's)70.07 ★66.17 / 70.49.41 ★81.56 / 89.8No: N short (66.2 of 70.4 %); P short (81.6 of 89.8 %)0.00

No treatment these routings use has costs yet. Enter them on each treatment's Cost tab to compare the routings' life-cycle cost.

What Routing 2 changes from Routing 1 (and filters in series: equivalent treatment depth)

CatchmentDrains toTreatment usedLeft out

No routing meets the required removal yet. Try a larger treatment, another treatment, or treatments in series, in a copy of a routing.