How this treatment's values are worked out: the equations, then the values they are worked with (v1's Equations button). A change on the Entry or Sizing tab shows here at once.
Treatment Depth (in) = Retention Volume (ac-ft) / Contributing Area (ac) x 12
Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.
The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.
N and P removal are equal to the hydraulic capture efficiency.
| Variable | Current value |
|---|---|
| Retention Volume | 0.400 ac-ft |
| Contributing Area | 6.000 ac |
| Watershed Area | 6.000 ac |
| Non-DCIA Curve Number | 75 |
| DCIA Percent | 25 % |
| Rainfall Zone | Florida Zone 2 |
| Treatment Depth | 0.800 in |
| Hydraulic Capture | 81.3 % |
| Treatment Rate | (no media mix) |
| N removal | 81.3 % |
| P removal | 81.3 % |