Retention

Retention basins routed in series — Retention on Upstream subdivision (stand-alone: this catchment's runoff only)
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

Retention Input Variables

Treatment Depth0.50 in
Retention Volume0.865 ac-ft
Time to Recover Design Volume0.00 hr

Watershed Characteristics

Watershed Area20.75 acres
Contributing Area to BMP20.75 ac
Watershed Non-DCIA Curve Number (0-100)76
Watershed DCIA Percent17.90 %
Rainfall ZoneFlorida Zone 4
Rainfall52.00 in

Surface Water Discharge

Provided Nitrogen Treatment Efficiency65.4 %
Provided Phosphorus Treatment Efficiency65.4 %

Groundwater Discharge (Stand-Alone)

Average Annual Recharge0.00 MG/yr
TN Mass Load30.55 kg/yr
TN Concentration0.00 mg/L
TP Mass Load7.62 kg/yr
TP Concentration0.00 mg/L

Surface Discharge Load Diagram for Retention (stand-alone)

Runoff input is only from this catchment, no routing is performed here

Load

N46.73 kg/yr
P11.66 kg/yr
Q20.87 ac-ft/yr

Treatment

N65 %
P65 %

Surface Discharge

N16.18 kg/yr
P4.04 kg/yr
Q7.23 ac-ft/yr

Mass Reduction

N30.55 kg/yr
P7.62 kg/yr
Q13.65 ac-ft/yr

Equations

The equations behind the values above, and the values they are worked with (v1's Equations page).

Retention — Equations

Equations

Treatment Depth (in) = Retention Volume (ac-ft) / Contributing Area (ac) x 12

Notes

Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.

The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.

N and P removal are equal to the hydraulic capture efficiency.

Values

VariableCurrent value
Retention Volume0.865 ac-ft
Contributing Area20.750 ac
Watershed Area20.750 ac
Non-DCIA Curve Number76.1
DCIA Percent17.9 %
Rainfall ZoneFlorida Zone 4
Treatment Depth0.500 in
Hydraulic Capture65.4 %
Treatment Rate(no media mix)
N removal65.4 %
P removal65.4 %