Retention

Retention basins routed in series — Retention on Downstream commercial (stand-alone: this catchment's runoff only)
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

Retention Input Variables

Treatment Depth0.60 in
Retention Volume1.870 ac-ft
Time to Recover Design Volume0.00 hr

Watershed Characteristics

Watershed Area37.41 acres
Contributing Area to BMP37.41 ac
Watershed Non-DCIA Curve Number (0-100)84
Watershed DCIA Percent19.00 %
Rainfall ZoneFlorida Zone 4
Rainfall52.00 in

Surface Water Discharge

Provided Nitrogen Treatment Efficiency62.4 %
Provided Phosphorus Treatment Efficiency62.4 %

Groundwater Discharge (Stand-Alone)

Average Annual Recharge0.00 MG/yr
TN Mass Load66.81 kg/yr
TN Concentration0.00 mg/L
TP Mass Load16.67 kg/yr
TP Concentration0.00 mg/L

Surface Discharge Load Diagram for Retention (stand-alone)

Runoff input is only from this catchment, no routing is performed here

Load

N107.12 kg/yr
P26.72 kg/yr
Q47.84 ac-ft/yr

Treatment

N62 %
P62 %

Surface Discharge

N40.31 kg/yr
P10.06 kg/yr
Q18.00 ac-ft/yr

Mass Reduction

N66.81 kg/yr
P16.67 kg/yr
Q29.84 ac-ft/yr

Equations

The equations behind the values above, and the values they are worked with (v1's Equations page).

Retention — Equations

Equations

Treatment Depth (in) = Retention Volume (ac-ft) / Contributing Area (ac) x 12

Notes

Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.

The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.

N and P removal are equal to the hydraulic capture efficiency.

Values

VariableCurrent value
Retention Volume1.870 ac-ft
Contributing Area37.410 ac
Watershed Area37.410 ac
Non-DCIA Curve Number84
DCIA Percent19 %
Rainfall ZoneFlorida Zone 4
Treatment Depth0.600 in
Hydraulic Capture62.4 %