| Watershed Area | 5.00 acres |
| Contributing Area to BMP | 5.00 ac |
| Watershed Non-DCIA Curve Number (0-100) | 80 |
| Watershed DCIA Percent | 60.00 % |
| Rainfall Zone | Florida Zone 5 |
| Rainfall | 61.00 in |
| Pavement Surface Area | 2.04 acres |
| Treatment Depth | 1.42 in |
| Permanent Pool Volume | 3.81 ac-ft |
| Permanent Pool Volume for 31 days residence | 1.18 ac-ft |
| Average Residence Time | 100.00 days |
| Has Littoral Zone | Yes |
| Wetland Efficiency Credit | 0.00 % |
| Nitrogen Treatment Efficiency (Series Contribution) | 9.52 % |
| Phosphorus Treatment Efficiency (Series Contribution) | 17.12 % |
| Average Effective Residence Time | 477.40 days |
When all upstream BMPs consist of Retention BMPs, the sum of the treatment depths are used to calculate efficiency. These are titled Equivalent Treatment Depth and Equivalent Treatment Efficiency.
The wet detention is then applied to what this system passes on, which gives the treatment efficiency of the Multiple BMP.
| Parameter | Value |
|---|---|
| Equivalent Treatment Depth (in) | 1.420 |
| Equivalent Treatment Efficiency (%) | 79.053 |
| Multiple BMP Provided N Treatment Efficiency (%) | 89 |
| Multiple BMP Provided P Treatment Efficiency (%) | 96 |
| Provided Nitrogen Treatment Efficiency | 88.6 % |
| Provided Phosphorus Treatment Efficiency | 96.2 % |
| Load N: 21.43 kg/yr P: 2.97 kg/yr Q: 13.90 ac-ft/yr | → | Treatment N: 89 % P: 96 % Q: 79 % | → | Surface Discharge N: 2.45 kg/yr P: 0.11 kg/yr Q: 2.91 ac-ft/yr |
| ↓ | ||||
| Mass Reduction N: 18.98 kg/yr P: 2.85 kg/yr Q: 10.99 ac-ft/yr |
The following calculations are based on the mean annual stormwater mass
remaining in the wet detention pond. The equations are from Harper and Baker (2007), Section 6.4.2 (pages 6-47 to 6-49),
and valid for anoxic depths from 0.8 to 29.5 feet.
WET DETENTION AS A FIRST BMP: Highway Section 206
| Parameter | Value |
|---|---|
| Overall Provided Phosphorus Treatment Efficiency (%) | 96.173 |
| Mean Annual Pond TP Concentration (ug/l) | 6.621 |
| Mean chlorophyll-a concentration (mg/m^3) | 2.903 |
| Mean Secchi Disk Depth (m) | 2.802 |
| Anoxic Pool Depth (ft) | 27.996 |
Note: If anoxic depth < pond depth, recalculate permanent pool volume using the anoxic
depth and re-enter the permanent pool volume.
The equations behind the values above, and the values they are worked with (v1's Equations page).
Case type: Retention to Wet Detention. Calculation used: Retention to Wet Detention (combined retention system, routed).
Retention [BMP 1 (Permeable Pavement)] → Routed wet detention [BMP 2 (Wet Detention)]
| Segment | BMPs | How it is calculated |
|---|---|---|
| Retention | BMP 1 (Permeable Pavement) | Treatment depths summed (Equivalent Treatment Depth); removal e from the retention lookup tables |
| Routed wet detention | BMP 2 (Wet Detention) | Effective Residence Time from the volume the retention passes on; combined as e + (100 - e)(D/100 - a/100 x e/100), a = 10 (N), 20 (P) |
Equivalent Treatment Depth (in) = sum of the Treatment Depths of the retention BMPs
Equivalent Treatment Efficiency e (%) = retention lookup (Equivalent Treatment Depth, non-DCIA CN, DCIA %, rainfall zone)
Volume to pond (ac-ft/yr) = Runoff x (100 - e) / 100
Effective Residence Time (days) = Permanent Pool Volume (ac-ft) / Volume to pond (ac-ft/yr) x 365
D = the pond's removal at the Effective Residence Time
Pond series contribution (%) = (100 - e) x (D / 100 - a / 100 x e / 100), a = 10 for N, 20 for P (not below 0)
Removal (%) = e + pond series contribution
The Multiple BMP detects its scenario from the BMPs in the series and uses the calculation named above.
The steps table lists every calculation in the order it was made, with the values used.
Each BMP's section shows its own equations and its values as they stand after the series calculation.
When all upstream BMPs consist of Retention BMPs, the sum of the treatment depths are used to calculate efficiency. These are titled Equivalent Treatment Depth and Equivalent Treatment Efficiency.
The wet detention is then applied to what this system passes on, which gives the treatment efficiency of the Multiple BMP.
| Variable | Current value |
|---|---|
| Scenario | Retention to Wet Detention |
| Calculation used | Retention to Wet Detention (combined retention system, routed) |
| Runoff into the series | 13.903 ac-ft/yr |
| N load into the series | 21.428 kg/yr |
| P load into the series | 2.966 kg/yr |
| Equivalent Treatment Depth | 1.42 in |
| Equivalent Treatment Efficiency (e) | 79.053 % |
| Hydraulic Capture | 79.1 % |
| N removal (Multiple BMP) | 88.6 % |
| P removal (Multiple BMP) | 96.2 % |
| N load out (surface discharge) | 2.449 kg/yr |
| P load out (surface discharge) | 0.114 kg/yr |
| # | Step | Calculation (values used) | Result |
|---|---|---|---|
| 1 | Inflow to the series | catchment runoff and loads | Q 13.903 ac-ft/yr, N 21.428 kg/yr, P 2.966 kg/yr |
| 2 | Equivalent Treatment Depth | BMP 1 (Permeable Pavement) 1.42 in | 1.42 in |
| 3 | Equivalent Treatment Efficiency (e) | retention lookup at 1.42 in, non-DCIA CN 80, DCIA 60 %, Florida Zone 5 | 79.05 % |
| 4 | Volume passed to the pond | 13.903 x (100 - 79.053) / 100 | 2.912 ac-ft/yr |
| 5 | Effective Residence Time | 3.809 ac-ft / 2.912 ac-ft/yr x 365 | 477.4 days |
| 6 | Pond removal D at that residence time | wet detention N and P equations, + 10 points (littoral zone credit) | N 53.35 %, P 97.54 % |
| 7 | Pond series contribution | N: (100 - 79.053) x (53.352/100 - 10/100 x 79.053/100); P: (100 - 79.053) x (97.539/100 - 20/100 x 79.053/100) (not below 0) | N 9.52 %, P 17.12 % |
| 8 | Removal through the pond (e + pond contribution) | N: 79.053 + 9.52; P: 79.053 + 17.119 | N 88.57 %, P 96.17 % |
| 9 | Loads out of the retention system | load in x (100 - e) / 100 | N 4.488 kg/yr, P 0.621 kg/yr |
| 10 | Loads out of the Wet Detention | its load in, less its series contribution expressed on the flow reaching it | N 2.449 kg/yr, P 0.114 kg/yr |
Part of the combined retention system: its Treatment Depth is added into the Equivalent Treatment Depth. Its own N and P removal below is not applied separately.
Equations
Storage (ac-ft) = Surface Area (ac) x Sum over layers [Layer Thickness (in) x Sustainable Void (%) / 100] x Layer Scale Factor / 12
Treatment Depth (in) = Storage / Watershed Area (ac) x 12
Notes
Sizing scales every pavement layer by the same factor: 1.0 is the layers as entered, 1.5 makes each layer half again as thick. Apply multiplies each layer thickness by the factor; Cancel leaves the layers as they were.
With no layers entered, sizing starts from 12 in of User Defined(20).
Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.
The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.
N and P removal are equal to the hydraulic capture efficiency.
A recovery-time adjustment for Time to Recover Design Volume is added to the capture efficiency and to N and P removal (see Recovery-Time Adjustment).
Values
| Variable | Current value |
|---|---|
| Contributing Area | 2.960 ac |
| Watershed Area | 5.000 ac |
| Non-DCIA Curve Number | 80 |
| DCIA Percent | 60 % |
| Rainfall Zone | Florida Zone 5 |
| Treatment Depth | 1.420 in |
| Hydraulic Capture | 79.1 % |
| Treatment Rate | (no media mix) |
| N removal | 79.1 % |
| P removal | 79.1 % |
Receives what the retention system passes on; its residence time is re-derived from that volume (see the steps above).
Equations
Residence Time rt (days) = Permanent Pool Volume (ac-ft) / Annual Runoff Volume (ac-ft) x 365
N removal (%) = 43.75 x rt / (4.38 + rt)
P removal (%) = 40.13 + 6.372 x ln(rt) + 0.213 x [ln(rt)]^2
Littoral zone: N removal = N removal + Littoral Zone Credit, P removal = P removal + Littoral Zone Credit (credit 0 to 10 %; none without one)
Wetland credit: N removal = N removal + Wetland Efficiency Credit x (100 - N removal) / 100
P removal = P removal + Wetland Efficiency Credit x (100 - P removal) / 100
Notes
Residence Time is capped at 200 days unless ART > 200 is allowed.
The littoral zone credit is added before the wetland credit (BMPFast 2: the equations are a pond without a littoral zone).
N and P removal cannot exceed 100%.
Values
| Variable | Current value |
|---|---|
| Wetland Efficiency Credit | 0.00 % |
| Permanent Pool Volume | 3.81 ac-ft |
| Annual Runoff Volume | 13.90 ac-ft |
| Treatment Rate | (no media mix) |
| N removal | 53.4 % |
| P removal | 97.5 % |
| Effective Residence Time (routed) | 477.4 days |
| Pond N removal at that residence time | 43.352 % |
| Pond P removal at that residence time | 96.173 % |
| N series contribution | 9.52 % |
| P series contribution | 17.119 % |