BMPs in Series

Ex # 5 ret to ret one catch — BMPs in Series on Highway Section 206 (stand-alone: this catchment's runoff only)
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

Multiple BMP in Series

Watershed Characteristics

Watershed Area5.00 acres
Contributing Area to BMP5.00 ac
Watershed Non-DCIA Curve Number (0-100)80
Watershed DCIA Percent60.00 %
Rainfall ZoneFlorida Zone 5
Rainfall61.00 in

BMP in Series Number: 1 (BMP Type: Permeable Pavement)

Pavement Surface Area1.00 acres
Treatment Depth0.66 in

BMP in Series Number: 2 (BMP Type: Retention)

Treatment Depth0.75 in
Retention Volume0.313 ac-ft
Time to Recover Design Volume72.00 hr
Provided Nitrogen Treatment Efficiency62.1 %
Provided Phosphorus Treatment Efficiency62.1 %

Equivalent Treatment Depth and Efficiency (Retention in Series)

When all upstream BMPs consist of Retention BMPs, the sum of the treatment depths are used to calculate efficiency. These are titled Equivalent Treatment Depth and Equivalent Treatment Efficiency.

There is no downstream BMP in this series, so this efficiency is also the treatment efficiency of the Multiple BMP.

ParameterValue
Equivalent Treatment Depth (in)1.411
Equivalent Treatment Efficiency (%)78.908
Multiple BMP Provided N Treatment Efficiency (%)79
Multiple BMP Provided P Treatment Efficiency (%)79

Surface Water Discharge

Provided Nitrogen Treatment Efficiency78.9 %
Provided Phosphorus Treatment Efficiency78.9 %

Load for Multiple BMP in Series

Load N: 21.43 kg/yr P: 2.97 kg/yr Q: 13.90 ac-ft/yr→Treatment N: 79 % P: 79 % Q: 79 %→Surface Discharge N: 4.50 kg/yr P: 0.62 kg/yr Q: 2.93 ac-ft/yr
↓
Mass Reduction N: 16.93 kg/yr P: 2.34 kg/yr Q: 10.97 ac-ft/yr

Equations

The equations behind the values above, and the values they are worked with (v1's Equations page).

Multiple BMP in Series — Equations

System case

Case type: Retention in Series. Calculation used: Retention in Series (one combined retention system).

Retention system (2 retention BMPs as one) [BMP 1 (Permeable Pavement) + BMP 2 (Retention)]

SegmentBMPsHow it is calculated
Retention system (2 retention BMPs as one)BMP 1 (Permeable Pavement) + BMP 2 (Retention)Treatment depths summed (Equivalent Treatment Depth); removal e from the retention lookup tables; e is the Multiple BMP's removal

Equations

Equivalent Treatment Depth (in) = sum of the Treatment Depths of the retention BMPs

Equivalent Treatment Efficiency e (%) = retention lookup (Equivalent Treatment Depth, non-DCIA CN, DCIA %, rainfall zone)

N removal = P removal = Hydraulic Capture = e

Notes

The Multiple BMP detects its scenario from the BMPs in the series and uses the calculation named above.

The steps table lists every calculation in the order it was made, with the values used.

Each BMP's section shows its own equations and its values as they stand after the series calculation.

When all upstream BMPs consist of Retention BMPs, the sum of the treatment depths are used to calculate efficiency. These are titled Equivalent Treatment Depth and Equivalent Treatment Efficiency.

There is no downstream BMP in this series, so this efficiency is also the treatment efficiency of the Multiple BMP.

Values

VariableCurrent value
ScenarioRetention in Series
Calculation usedRetention in Series (one combined retention system)
Runoff into the series13.903 ac-ft/yr
N load into the series21.428 kg/yr
P load into the series2.966 kg/yr
Equivalent Treatment Depth1.411 in
Equivalent Treatment Efficiency (e)78.908 %
Hydraulic Capture78.9 %
N removal (Multiple BMP)78.9 %
P removal (Multiple BMP)78.9 %
N load out (surface discharge)4.5 kg/yr
P load out (surface discharge)0.623 kg/yr

Calculation steps (values as used)

#StepCalculation (values used)Result
1Inflow to the seriescatchment runoff and loadsQ 13.903 ac-ft/yr, N 21.428 kg/yr, P 2.966 kg/yr
2Equivalent Treatment DepthBMP 1 (Permeable Pavement) 0.66 in + BMP 2 (Retention) 0.751 in1.411 in
3Equivalent Treatment Efficiency (e)retention lookup at 1.411 in, non-DCIA CN 80, DCIA 60 %, Florida Zone 578.91 %
4Multiple BMP removalN = P = Hydraulic Capture = e78.91 %

BMP 1: Permeable Pavement

Part of the combined retention system: its Treatment Depth is added into the Equivalent Treatment Depth. Its own N and P removal below is not applied separately.

Equations

Storage (ac-ft) = Surface Area (ac) x Sum over layers [Layer Thickness (in) x Sustainable Void (%) / 100] x Layer Scale Factor / 12

Treatment Depth (in) = Storage / Watershed Area (ac) x 12

Notes

Sizing scales every pavement layer by the same factor: 1.0 is the layers as entered, 1.5 makes each layer half again as thick. Apply multiplies each layer thickness by the factor; Cancel leaves the layers as they were.

With no layers entered, sizing starts from 12 in of User Defined(20).

Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.

The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.

N and P removal are equal to the hydraulic capture efficiency.

A recovery-time adjustment for Time to Recover Design Volume is added to the capture efficiency and to N and P removal (see Recovery-Time Adjustment).

Values

VariableCurrent value
Contributing Area4.000 ac
Watershed Area5.000 ac
Non-DCIA Curve Number80
DCIA Percent60 %
Rainfall ZoneFlorida Zone 5
Treatment Depth0.660 in
Hydraulic Capture57.9 %
Treatment Rate(no media mix)
N removal57.9 %
P removal57.9 %

BMP 2: Retention

Part of the combined retention system: its Treatment Depth is added into the Equivalent Treatment Depth. Its own N and P removal below is not applied separately.

Equations

Treatment Depth (in) = Retention Volume (ac-ft) / Contributing Area (ac) x 12

Notes

Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.

The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.

N and P removal are equal to the hydraulic capture efficiency.

Values

VariableCurrent value
Retention Volume0.313 ac-ft
Contributing Area5.000 ac
Watershed Area5.000 ac
Non-DCIA Curve Number80
DCIA Percent60 %
Rainfall ZoneFlorida Zone 5
Treatment Depth0.751 in
Hydraulic Capture62.1 %
Treatment Rate(no media mix)
N removal62.1 %
P removal62.1 %