BMPs in Series — calculations

Example 6 Multiple BMP _ Cost — BMPs in Series on Road and Commercial Center (stand-alone: this catchment's runoff only)
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

How this treatment's values are worked out: the equations, then the values they are worked with (v1's Equations button). A change on the Entry or Sizing tab shows here at once.

System case

Case type: Retention in Series. Calculation used: Retention in Series (one combined retention system).

Retention system (3 retention BMPs as one) [BMP 1 (Tree Well) + BMP 2 (Exfiltration) + BMP 3 (Retention)]

SegmentBMPsHow it is calculated
Retention system (3 retention BMPs as one)BMP 1 (Tree Well) + BMP 2 (Exfiltration) + BMP 3 (Retention)Treatment depths summed (Equivalent Treatment Depth); removal e from the retention lookup tables; e is the Multiple BMP's removal

Equations

Equivalent Treatment Depth (in) = sum of the Treatment Depths of the retention BMPs

Equivalent Treatment Efficiency e (%) = retention lookup (Equivalent Treatment Depth, non-DCIA CN, DCIA %, rainfall zone)

N removal = P removal = Hydraulic Capture = e

Notes

The Multiple BMP detects its scenario from the BMPs in the series and uses the calculation named above.

The steps table lists every calculation in the order it was made, with the values used.

Each BMP's section shows its own equations and its values as they stand after the series calculation.

When all upstream BMPs consist of Retention BMPs, the sum of the treatment depths are used to calculate efficiency. These are titled Equivalent Treatment Depth and Equivalent Treatment Efficiency.

There is no downstream BMP in this series, so this efficiency is also the treatment efficiency of the Multiple BMP.

Values

VariableCurrent value
ScenarioRetention in Series
Calculation usedRetention in Series (one combined retention system)
Runoff into the series14.841 ac-ft/yr
N load into the series17.018 kg/yr
P load into the series3.44 kg/yr
Equivalent Treatment Depth1.333 in
Equivalent Treatment Efficiency (e)83.3 %
Hydraulic Capture83.3 %
N removal (Multiple BMP)83.3 %
P removal (Multiple BMP)83.3 %
N load out (surface discharge)2.893 kg/yr
P load out (surface discharge)0.585 kg/yr

Calculation steps (values as used)

#StepCalculation (values used)Result
1Inflow to the seriescatchment runoff and loadsQ 14.841 ac-ft/yr, N 17.018 kg/yr, P 3.44 kg/yr
2Equivalent Treatment DepthBMP 1 (Tree Well) 0.195 in + BMP 2 (Exfiltration) 0.138 in + BMP 3 (Retention) 1 in1.333 in
3Equivalent Treatment Efficiency (e)retention lookup at 1.333 in, non-DCIA CN 85, DCIA 65 %, Florida Zone 283.3 %
4Multiple BMP removalN = P = Hydraulic Capture = e83.3 %

BMP 1: Tree Well retention

Part of the combined retention system: its Treatment Depth is added into the Equivalent Treatment Depth. Its own N and P removal below is not applied separately.

Equations

Storage per Area (ac-ft) = Length x Width x (Depth + Soil Storage Capacity) / 43560

Treatment Volume (ac-ft) = Storage per Area x Number of Similar Areas

Treatment Depth (in) = Treatment Volume / Watershed Area (ac) x 12

Notes

Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.

The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.

N and P removal are equal to the hydraulic capture efficiency.

Values

VariableCurrent value
Vegetated Area (Tree Well) depth4.00 ft
Vegetated Area (Tree Well) Length5.00 ft
Vegetated Area (Tree Well) Width5.00 ft
Sustainable water storage capacity of the soil0.25 ft
Number of Similar Areas in Watershed40
Contributing Area6.000 ac
Watershed Area6.000 ac
Non-DCIA Curve Number85
DCIA Percent65 %
Rainfall ZoneFlorida Zone 2
Treatment Depth0.195 in
Hydraulic Capture26.3 %
Treatment Rate(no media mix)
N removal26.3 %
P removal26.3 %

BMP 2: Exfiltration

Part of the combined retention system: its Treatment Depth is added into the Equivalent Treatment Depth. Its own N and P removal below is not applied separately.

Equations

Pipe Volume (cf) = pi x (Pipe Span / 24) x (Pipe Rise / 24) x Pipe Length

Trench Volume (cf) = (Trench Width x Trench Depth x Trench Length - Pipe Volume) x Void Ratio

Treatment Volume (ac-ft) = (Pipe Volume + Trench Volume) / 43560

Treatment Depth (in) = Treatment Volume / Contributing Area (ac) x 12

Notes

Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.

The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.

N and P removal are equal to the hydraulic capture efficiency.

Values

VariableCurrent value
Pipe Span48.00 in
Pipe Rise48.00 in
Pipe Length200.00 ft
Trench Length200.00 ft
Trench/Vault Width5.00 ft
Trench Depth4.50 ft
Void Ratio0.25 fraction
Contributing Area6.000 ac
Watershed Area6.000 ac
Non-DCIA Curve Number85
DCIA Percent65 %
Rainfall ZoneFlorida Zone 2
Treatment Depth0.138 in
Hydraulic Capture18.6 %
Treatment Rate(no media mix)
N removal18.6 %
P removal18.6 %

BMP 3: Retention

Part of the combined retention system: its Treatment Depth is added into the Equivalent Treatment Depth. Its own N and P removal below is not applied separately.

Equations

Treatment Depth (in) = Retention Volume (ac-ft) / Contributing Area (ac) x 12

Notes

Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.

The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.

N and P removal are equal to the hydraulic capture efficiency.

Values

VariableCurrent value
Retention Volume0.500 ac-ft
Contributing Area6.000 ac
Watershed Area6.000 ac
Non-DCIA Curve Number85
DCIA Percent65 %
Rainfall ZoneFlorida Zone 2
Treatment Depth1.000 in
Hydraulic Capture75.9 %
Treatment Rate(no media mix)
N removal75.9 %
P removal75.9 %