Media Filter Service Life — calculations

Ex # 5 ret to det one catch
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

How the calculator's results are worked out: the equations, then the values they are worked with (v1's Equations button). A change on the Entry tab shows here at once.

Equations

Equation
Treatment Depth (in) = Filter Surface Area (sf) x Rate (gpm/sf) / (18.85 x Area Discharging to Filter (ac)) (as in Filter Sizing)
Filter TP removal (%) = Capture (retention curves at the Treatment Depth) x Media P reduction / 100
TP reaching the filter (kg/yr) = Catchment TP load (kg/yr) x (100 - Upstream TP removal (%)) / 100
TP retained by the filter (kg/yr) = TP reaching the filter x Filter TP removal / 100
Media Volume (cf) = Filter Surface Area (sf) x Media Layer Depth (in) / 12
Media capacity (kg OP) = Media Volume (cf) x Saturated Weight (lb/cf) x 454 g/lb x Sorption Rate (mg OP/g) / 10^6
OP load on the media (kg/yr) = OP fraction x TP retained by the filter
Service Life (yr) = Media capacity (kg OP) / OP load on the media (kg OP/yr)

Notes

Note
The surface area changes both the media volume and the Treatment Depth: a larger filter holds more media but also captures and retains more phosphorus, so the life rises less than the volume.
The retention curves end at a 4.00 in Treatment Depth; above it the capture no longer rises and the life grows with the media volume alone.
The phosphorus reaching the filter is what the upstream BMP passes on; the media holds back the share given by the filter's TP removal.
Sorption Rate and Saturated Weight come from the media mix (Media Mix Library for a mix of your own).
An OP fraction of 1.0 assumes all the phosphorus the media holds is orthophosphorus, which gives the shortest life.
Only this catchment's runoff is counted; flow routed here from other catchments is not.
How sensitive the life is to each input is shown on the Media Filter Service Life help page.

Upstream treatment, Retention: Treatment Depth (in) = Retention Volume (ac-ft) / Contributing Area (ac) x 12 Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth. The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone. N and P removal are equal to the hydraulic capture efficiency.