Media Filter Service Life

Ex # 5 ret to det one catch
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

Method

What kind of treatmentSurface Discharge Filter: life against its surface area

Filter and what feeds it

CatchmentHighway Section 206
Surface Discharge FilterSurface Discharge Filter
Upstream treatmentRetention
UpstreamRemoves nitrogen 62.1 %, phosphorus 62.1 %; captures 62.1 %, so 2.272 of 6.000 ac drains to the filter.
Filter mediaB&G CTS24
Treatment rate0.052 gpm/sf

Filter surface area

Filter surface area2,175 sf
Starting area405 sf, the area that meets the removal targets (nitrogen 70 %, phosphorus 80 %) — you typed another; clear the box to go back to it
Treatment depth2.641 in

Media

Media layer depth24.00 in
Media depth fromyou
Orthophosphorus share of the phosphorus1.00
The media's valuesRate 0.052 gpm/sf, sorption 0.2 mg OP/g, saturated weight 95 lb/cf, phosphorus reduction 95 %

Results

Service life38.7 years
Phosphorus reaching and held by the filter1.123 kg/yr reaches the filter; it holds back 0.968 kg/yr (its phosphorus removal 86.3 %); orthophosphorus load on the media 0.968 kg/yr
Media volume and capacity4,350 cf (2,175 sf × 24 in / 12); it holds 37.52 kg of orthophosphorus

Chart

Chart the life againstFilter surface area
Chart areas from 0 to5,000 sf

Equations

Equation
Treatment Depth (in) = Filter Surface Area (sf) x Rate (gpm/sf) / (18.85 x Area Discharging to Filter (ac)) (as in Filter Sizing)
Filter TP removal (%) = Capture (retention curves at the Treatment Depth) x Media P reduction / 100
TP reaching the filter (kg/yr) = Catchment TP load (kg/yr) x (100 - Upstream TP removal (%)) / 100
TP retained by the filter (kg/yr) = TP reaching the filter x Filter TP removal / 100
Media Volume (cf) = Filter Surface Area (sf) x Media Layer Depth (in) / 12
Media capacity (kg OP) = Media Volume (cf) x Saturated Weight (lb/cf) x 454 g/lb x Sorption Rate (mg OP/g) / 10^6
OP load on the media (kg/yr) = OP fraction x TP retained by the filter
Service Life (yr) = Media capacity (kg OP) / OP load on the media (kg OP/yr)

Notes

Note
The surface area changes both the media volume and the Treatment Depth: a larger filter holds more media but also captures and retains more phosphorus, so the life rises less than the volume.
The retention curves end at a 4.00 in Treatment Depth; above it the capture no longer rises and the life grows with the media volume alone.
The phosphorus reaching the filter is what the upstream BMP passes on; the media holds back the share given by the filter's TP removal.
Sorption Rate and Saturated Weight come from the media mix (Media Mix Library for a mix of your own).
An OP fraction of 1.0 assumes all the phosphorus the media holds is orthophosphorus, which gives the shortest life.
Only this catchment's runoff is counted; flow routed here from other catchments is not.
How sensitive the life is to each input is shown on the Media Filter Service Life help page.

Upstream treatment, Retention: Treatment Depth (in) = Retention Volume (ac-ft) / Contributing Area (ac) x 12 Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth. The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone. N and P removal are equal to the hydraulic capture efficiency.