Media Filter Service Life
Ex # 5 ret to det one catch
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00
Method
| What kind of treatment | Surface Discharge Filter: life against its surface area |
Filter and what feeds it
| Catchment | Highway Section 206 |
| Surface Discharge Filter | Surface Discharge Filter |
| Upstream treatment | Retention |
| Upstream | Removes nitrogen 62.1 %, phosphorus 62.1 %; captures 62.1 %, so 2.272 of 6.000 ac drains to the filter. |
| Filter media | B&G CTS24 |
| Treatment rate | 0.052 gpm/sf |
Filter surface area
| Filter surface area | 2,175 sf |
| Starting area | 405 sf, the area that meets the removal targets (nitrogen 70 %, phosphorus 80 %) — you typed another; clear the box to go back to it |
| Treatment depth | 2.641 in |
Media
| Media layer depth | 24.00 in |
| Media depth from | you |
| Orthophosphorus share of the phosphorus | 1.00 |
| The media's values | Rate 0.052 gpm/sf, sorption 0.2 mg OP/g, saturated weight 95 lb/cf, phosphorus reduction 95 % |
Results
| Service life | 38.7 years |
| Phosphorus reaching and held by the filter | 1.123 kg/yr reaches the filter; it holds back 0.968 kg/yr (its phosphorus removal 86.3 %); orthophosphorus load on the media 0.968 kg/yr |
| Media volume and capacity | 4,350 cf (2,175 sf × 24 in / 12); it holds 37.52 kg of orthophosphorus |
Chart
| Chart the life against | Filter surface area |
| Chart areas from 0 to | 5,000 sf |
Equations
| Equation |
| Treatment Depth (in) = Filter Surface Area (sf) x Rate (gpm/sf) / (18.85 x Area Discharging to Filter (ac)) (as in Filter Sizing) |
| Filter TP removal (%) = Capture (retention curves at the Treatment Depth) x Media P reduction / 100 |
| TP reaching the filter (kg/yr) = Catchment TP load (kg/yr) x (100 - Upstream TP removal (%)) / 100 |
| TP retained by the filter (kg/yr) = TP reaching the filter x Filter TP removal / 100 |
| Media Volume (cf) = Filter Surface Area (sf) x Media Layer Depth (in) / 12 |
| Media capacity (kg OP) = Media Volume (cf) x Saturated Weight (lb/cf) x 454 g/lb x Sorption Rate (mg OP/g) / 10^6 |
| OP load on the media (kg/yr) = OP fraction x TP retained by the filter |
| Service Life (yr) = Media capacity (kg OP) / OP load on the media (kg OP/yr) |
Notes
| Note |
| The surface area changes both the media volume and the Treatment Depth: a larger filter holds more media but also captures and retains more phosphorus, so the life rises less than the volume. |
| The retention curves end at a 4.00 in Treatment Depth; above it the capture no longer rises and the life grows with the media volume alone. |
| The phosphorus reaching the filter is what the upstream BMP passes on; the media holds back the share given by the filter's TP removal. |
| Sorption Rate and Saturated Weight come from the media mix (Media Mix Library for a mix of your own). |
| An OP fraction of 1.0 assumes all the phosphorus the media holds is orthophosphorus, which gives the shortest life. |
| Only this catchment's runoff is counted; flow routed here from other catchments is not. |
| How sensitive the life is to each input is shown on the Media Filter Service Life help page. |
Upstream treatment, Retention: Treatment Depth (in) = Retention Volume (ac-ft) / Contributing Area (ac) x 12 Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth. The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone. N and P removal are equal to the hydraulic capture efficiency.