Stormwater Harvesting

Stormwater harvesting: 5 ac commercial site, Zone 5 — Stormwater Harvesting on Watershed (stand-alone: this catchment's runoff only)
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

Stormwater Harvesting Input Variables

Contributing Area to BMP5.00 ac
Total Area Available for Irrigation3.00 acres
Available Harvest Volume1.00 ac-ft
Available Harvest Rate0.80 in/week
Effective Impervious Area3.06 acres
Treatment Depth0.81 in

Water Budget

Water Use3.39 MGY
Harvested Water Supply3.15 MGY
Supplemental Water Needed0.24 MGY

Supplemental Water Needed = Water Use - Harvested Water Supply (0 when the supply covers the use): the irrigation water that must come from another source.

Watershed Characteristics

Watershed Area5.00 acres
Contributing Area to BMP5.00 ac
Watershed Non-DCIA Curve Number (0-100)80
Watershed DCIA Percent70.00 %
Rainfall ZoneFlorida Zone 5
Rainfall61.00 in

Surface Water Discharge

Provided Nitrogen Treatment Efficiency62.0 %
Provided Phosphorus Treatment Efficiency62.0 %

Surface Discharge Load Diagram for Stormwater Harvesting (stand-alone)

Runoff input is only from this catchment, no routing is performed here

Load

N46.11 kg/yr
P6.63 kg/yr
Q15.58 ac-ft/yr

Treatment

N62 %
P62 %

Surface Discharge

N17.51 kg/yr
P2.52 kg/yr
Q5.92 ac-ft/yr

Mass Reduction

N28.59 kg/yr
P4.11 kg/yr
Q9.66 ac-ft/yr

Equations

The equations behind the values above, and the values they are worked with (v1's Equations page).

Stormwater Harvesting — Equations

Equations

x = Harvest Volume (ac-ft) x 12 / (Watershed Area (ac) x ROC)

y = Harvest Rate (in/week) x Irrigation Area (ac) / 7 / (Watershed Area (ac) x ROC)

Harvest Efficiency (%) = REV table lookup of (x, y)

Water Use (MGY) = Harvest Rate (in/week) x 52 / 12 x Irrigation Area (ac) x 0.32585 MG/ac-ft

Harvested Water Supply (MGY) = Annual Runoff Volume (ac-ft/yr) x Harvest Efficiency / 100 x 0.32585 MG/ac-ft

Supplemental Water Needed (MGY) = Water Use - Harvested Water Supply (0 when the supply covers the use)

Notes

ROC is the catchment's annual runoff coefficient.

Harvest Efficiency is capped at 90%. Below 20%, the lowest REV curve, it is extended along the line between the 20% and 30% curves (beyond the published curves).

N and P removal are equal to the Harvest Efficiency.

Treatment Depth is back-calculated as the retention depth giving the same efficiency in the retention tables.

Values: the harvest efficiency is read from the REV curves of the Rainfall Zone. Non-DCIA Curve Number, DCIA Percent and Treatment Rate are listed for every retention-type BMP but are not used to calculate the harvest efficiency. Non-DCIA Curve Number and DCIA Percent are used only to back-calculate the Treatment Depth.

Values

VariableCurrent value
Available Harvest Volume1.00 ac-ft
Total Area Available for Irrigation3.00 acres
Available Harvest Rate0.80 in/week
Contributing Area5.000 ac
Watershed Area5.000 ac
Non-DCIA Curve Number80
DCIA Percent70 %
Rainfall ZoneFlorida Zone 5
Treatment Depth0.809 in
Hydraulic Capture62.0 %
Treatment Rate(no media mix)
N removal62.0 %
P removal62.0 %