Stormwater Harvesting

Stormwater harvesting: subdivision irrigating common areas — Stormwater Harvesting on Subdivision (stand-alone: this catchment's runoff only)
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

Stormwater Harvesting Input Variables

Contributing Area to BMP40.00 ac
Total Area Available for Irrigation12.00 acres
Available Harvest Volume6.00 ac-ft
Available Harvest Rate1.00 in/week
Effective Impervious Area10.48 acres
Treatment Depth1.35 in

Water Budget

Water Use16.94 MGY
Harvested Water Supply12.81 MGY
Supplemental Water Needed4.14 MGY

Supplemental Water Needed = Water Use - Harvested Water Supply (0 when the supply covers the use): the irrigation water that must come from another source.

Watershed Characteristics

Watershed Area40.00 acres
Contributing Area to BMP40.00 ac
Watershed Non-DCIA Curve Number (0-100)75
Watershed DCIA Percent25.00 %
Rainfall ZoneFlorida Zone 2
Rainfall50.00 in

Surface Water Discharge

Provided Nitrogen Treatment Efficiency90.0 %
Provided Phosphorus Treatment Efficiency90.0 %

Surface Discharge Load Diagram for Stormwater Harvesting (stand-alone)

Runoff input is only from this catchment, no routing is performed here

Load

N95.30 kg/yr
P17.61 kg/yr
Q43.67 ac-ft/yr

Treatment

N90 %
P90 %

Surface Discharge

N9.53 kg/yr
P1.76 kg/yr
Q4.37 ac-ft/yr

Mass Reduction

N85.77 kg/yr
P15.85 kg/yr
Q39.30 ac-ft/yr

Equations

The equations behind the values above, and the values they are worked with (v1's Equations page).

Stormwater Harvesting — Equations

Equations

x = Harvest Volume (ac-ft) x 12 / (Watershed Area (ac) x ROC)

y = Harvest Rate (in/week) x Irrigation Area (ac) / 7 / (Watershed Area (ac) x ROC)

Harvest Efficiency (%) = REV table lookup of (x, y)

Water Use (MGY) = Harvest Rate (in/week) x 52 / 12 x Irrigation Area (ac) x 0.32585 MG/ac-ft

Harvested Water Supply (MGY) = Annual Runoff Volume (ac-ft/yr) x Harvest Efficiency / 100 x 0.32585 MG/ac-ft

Supplemental Water Needed (MGY) = Water Use - Harvested Water Supply (0 when the supply covers the use)

Notes

ROC is the catchment's annual runoff coefficient.

Harvest Efficiency is capped at 90%. Below 20%, the lowest REV curve, it is extended along the line between the 20% and 30% curves (beyond the published curves).

N and P removal are equal to the Harvest Efficiency.

Treatment Depth is back-calculated as the retention depth giving the same efficiency in the retention tables.

Values: the harvest efficiency is read from the REV curves of the Rainfall Zone. Non-DCIA Curve Number, DCIA Percent and Treatment Rate are listed for every retention-type BMP but are not used to calculate the harvest efficiency. Non-DCIA Curve Number and DCIA Percent are used only to back-calculate the Treatment Depth.

Values

VariableCurrent value
Available Harvest Volume6.00 ac-ft
Total Area Available for Irrigation12.00 acres
Available Harvest Rate1.00 in/week
Contributing Area40.000 ac
Watershed Area40.000 ac
Non-DCIA Curve Number75
DCIA Percent25 %
Rainfall ZoneFlorida Zone 2
Treatment Depth1.350 in
Hydraulic Capture90.0 %
Treatment Rate(no media mix)
N removal90.0 %
P removal90.0 %