| Contributing Area to BMP | 40.00 ac |
| Total Area Available for Irrigation | 12.00 acres |
| Available Harvest Volume | 6.00 ac-ft |
| Available Harvest Rate | 1.00 in/week |
| Effective Impervious Area | 10.48 acres |
| Treatment Depth | 1.35 in |
| Water Use | 16.94 MGY |
| Harvested Water Supply | 12.81 MGY |
| Supplemental Water Needed | 4.14 MGY |
Supplemental Water Needed = Water Use - Harvested Water Supply (0 when the supply covers the use): the irrigation water that must come from another source.
| Watershed Area | 40.00 acres |
| Contributing Area to BMP | 40.00 ac |
| Watershed Non-DCIA Curve Number (0-100) | 75 |
| Watershed DCIA Percent | 25.00 % |
| Rainfall Zone | Florida Zone 2 |
| Rainfall | 50.00 in |
| Provided Nitrogen Treatment Efficiency | 90.0 % |
| Provided Phosphorus Treatment Efficiency | 90.0 % |
Runoff input is only from this catchment, no routing is performed here
| N | 95.30 kg/yr |
| P | 17.61 kg/yr |
| Q | 43.67 ac-ft/yr |
| N | 90 % |
| P | 90 % |
| N | 9.53 kg/yr |
| P | 1.76 kg/yr |
| Q | 4.37 ac-ft/yr |
| N | 85.77 kg/yr |
| P | 15.85 kg/yr |
| Q | 39.30 ac-ft/yr |
The equations behind the values above, and the values they are worked with (v1's Equations page).
x = Harvest Volume (ac-ft) x 12 / (Watershed Area (ac) x ROC)
y = Harvest Rate (in/week) x Irrigation Area (ac) / 7 / (Watershed Area (ac) x ROC)
Harvest Efficiency (%) = REV table lookup of (x, y)
Water Use (MGY) = Harvest Rate (in/week) x 52 / 12 x Irrigation Area (ac) x 0.32585 MG/ac-ft
Harvested Water Supply (MGY) = Annual Runoff Volume (ac-ft/yr) x Harvest Efficiency / 100 x 0.32585 MG/ac-ft
Supplemental Water Needed (MGY) = Water Use - Harvested Water Supply (0 when the supply covers the use)
ROC is the catchment's annual runoff coefficient.
Harvest Efficiency is capped at 90%. Below 20%, the lowest REV curve, it is extended along the line between the 20% and 30% curves (beyond the published curves).
N and P removal are equal to the Harvest Efficiency.
Treatment Depth is back-calculated as the retention depth giving the same efficiency in the retention tables.
Values: the harvest efficiency is read from the REV curves of the Rainfall Zone. Non-DCIA Curve Number, DCIA Percent and Treatment Rate are listed for every retention-type BMP but are not used to calculate the harvest efficiency. Non-DCIA Curve Number and DCIA Percent are used only to back-calculate the Treatment Depth.
| Variable | Current value |
|---|---|
| Available Harvest Volume | 6.00 ac-ft |
| Total Area Available for Irrigation | 12.00 acres |
| Available Harvest Rate | 1.00 in/week |
| Contributing Area | 40.000 ac |
| Watershed Area | 40.000 ac |
| Non-DCIA Curve Number | 75 |
| DCIA Percent | 25 % |
| Rainfall Zone | Florida Zone 2 |
| Treatment Depth | 1.350 in |
| Hydraulic Capture | 90.0 % |
| Treatment Rate | (no media mix) |
| N removal | 90.0 % |
| P removal | 90.0 % |