How this treatment's values are worked out: the equations, then the values they are worked with (v1's Equations button). A change on the Entry or Sizing tab shows here at once.
x = Harvest Volume (ac-ft) x 12 / (Watershed Area (ac) x ROC)
y = Harvest Rate (in/week) x Irrigation Area (ac) / 7 / (Watershed Area (ac) x ROC)
Harvest Efficiency (%) = REV table lookup of (x, y)
Water Use (MGY) = Harvest Rate (in/week) x 52 / 12 x Irrigation Area (ac) x 0.32585 MG/ac-ft
Harvested Water Supply (MGY) = Annual Runoff Volume (ac-ft/yr) x Harvest Efficiency / 100 x 0.32585 MG/ac-ft
Supplemental Water Needed (MGY) = Water Use - Harvested Water Supply (0 when the supply covers the use)
ROC is the catchment's annual runoff coefficient.
Harvest Efficiency is capped at 90%. Below 20%, the lowest REV curve, it is extended along the line between the 20% and 30% curves (beyond the published curves).
N and P removal are equal to the Harvest Efficiency.
Treatment Depth is back-calculated as the retention depth giving the same efficiency in the retention tables.
Values: the harvest efficiency is read from the REV curves of the Rainfall Zone. Non-DCIA Curve Number, DCIA Percent and Treatment Rate are listed for every retention-type BMP but are not used to calculate the harvest efficiency. Non-DCIA Curve Number and DCIA Percent are used only to back-calculate the Treatment Depth.
| Variable | Current value |
|---|---|
| Available Harvest Volume | 6.00 ac-ft |
| Total Area Available for Irrigation | 12.00 acres |
| Available Harvest Rate | 1.00 in/week |
| Contributing Area | 40.000 ac |
| Watershed Area | 40.000 ac |
| Non-DCIA Curve Number | 75 |
| DCIA Percent | 25 % |
| Rainfall Zone | Florida Zone 2 |
| Treatment Depth | 1.350 in |
| Hydraulic Capture | 90.0 % |
| Treatment Rate | (no media mix) |
| N removal | 90.0 % |
| P removal | 90.0 % |