User Defined BMP

User defined BMP: baffle box — User Defined BMP on Subdivision (stand-alone: this catchment's runoff only)
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

User Defined BMP Input Variables

User Defined BMPBaffle Boxes 2nd Gen
Contributing Area to BMP10.00 ac
Calculated Nitrogen Treatment Efficiency (as entered)19.00 %
Calculated Phosphorus Treatment Efficiency (as entered)35.00 %
Hydraulic Capture, entered (%; 0 = passes all its flow forward)35.0

Watershed Characteristics

Watershed Area10.00 acres
Contributing Area to BMP10.00 ac
Watershed Non-DCIA Curve Number (0-100)75
Watershed DCIA Percent25.00 %
Rainfall ZoneFlorida Zone 2
Rainfall50.00 in

Surface Water Discharge

Provided Nitrogen Treatment Efficiency19.0 %
Provided Phosphorus Treatment Efficiency35.0 %

Groundwater Discharge (Stand-Alone)

Average Annual Recharge0.00 MG/yr
TN Mass Load0.00 kg/yr
TN Concentration0.00 mg/L
TP Mass Load0.00 kg/yr
TP Concentration0.00 mg/L

Surface Discharge Load Diagram for User Defined BMP (stand-alone)

Runoff input is only from this catchment, no routing is performed here

Load

N23.82 kg/yr
P4.40 kg/yr
Q10.92 ac-ft/yr

Treatment

N19 %
P35 %

Surface Discharge

N19.30 kg/yr
P2.86 kg/yr
Q7.10 ac-ft/yr

Mass Reduction

N4.53 kg/yr
P1.54 kg/yr
Q3.82 ac-ft/yr

Equations

The equations behind the values above, and the values they are worked with (v1's Equations page).

User Defined BMP — Equations

Equations

N removal (%) = the Nitrogen removal efficiency entered

P removal (%) = the Phosphorus removal efficiency entered

Notes

A user-defined BMP has no sizing equations; its removal efficiencies are entered directly.

They are applied to the annual load reaching the BMP in the routing (treatment train) calculation.

Values

VariableCurrent value
Hydraulic Capture35.0 %
Treatment Rate(no media mix)
N removal19.0 %
P removal35.0 %