1The problem
Three catchments drain one into another, Upstream subdivision → Middle subdivision → Downstream commercial → outlet, and each is treated by a Surface Discharge Filter. Filters one after another can be calculated each on its own (the Handbook equation) or as one system (the equivalent treatment depth): the routing’s Surface discharge filters in series. Make one routing for each and compare.
| Input | Value | Source |
|---|---|---|
| Project (General Site Information) | ||
| Meteorological zone | Florida Zone 4 | Zone map (help page 815) |
| Mean annual rainfall | 52 in | Mean annual rainfall map (help page 815) |
| Performance standard (analysis type) | All sites non-exempted | Site (illustrative; the catchments of BMPFast sample project Detention Multiple catchments 2020 Manual pages 190 196) |
| Catchment 1: Upstream subdivision (Watershed Characteristics) | ||
| Land use, pre / post | Agricultural - Citrus / User Defined Values | Site (illustrative; the catchments of BMPFast sample project Detention Multiple catchments 2020 Manual pages 190 196) |
| Area, pre / post | 20.75 / 20.75 ac | Site (illustrative; the catchments of BMPFast sample project Detention Multiple catchments 2020 Manual pages 190 196) |
| Non-DCIA curve number, pre / post | 68.3 / 76.12 | Site (illustrative; the catchments of BMPFast sample project Detention Multiple catchments 2020 Manual pages 190 196) |
| DCIA, pre / post | 0 / 17.9 % | Site (illustrative; the catchments of BMPFast sample project Detention Multiple catchments 2020 Manual pages 190 196) |
| EMC TN, pre / post | 2.110 / 1.816 mg/L | BMPFast land use table (AH Vol I Table 9.2) |
| EMC TP, pre / post | 0.180 / 0.453 mg/L | BMPFast land use table (AH Vol I Table 9.2) |
| Catchment 2: Middle subdivision (Watershed Characteristics) | ||
| Land use, pre / post | Agricultural - Citrus / User Defined Values | Site (illustrative; the catchments of BMPFast sample project Detention Multiple catchments 2020 Manual pages 190 196) |
| Area, pre / post | 25.13 / 25.13 ac | Site (illustrative; the catchments of BMPFast sample project Detention Multiple catchments 2020 Manual pages 190 196) |
| Non-DCIA curve number, pre / post | 68.3 / 76.12 | Site (illustrative; the catchments of BMPFast sample project Detention Multiple catchments 2020 Manual pages 190 196) |
| DCIA, pre / post | 0 / 17.8 % | Site (illustrative; the catchments of BMPFast sample project Detention Multiple catchments 2020 Manual pages 190 196) |
| EMC TN, pre / post | 2.110 / 1.715 mg/L | BMPFast land use table (AH Vol I Table 9.2) |
| EMC TP, pre / post | 0.180 / 0.407 mg/L | BMPFast land use table (AH Vol I Table 9.2) |
| Catchment 3: Downstream commercial (Watershed Characteristics) | ||
| Land use, pre / post | Agricultural - Citrus / User Defined Values | Site (illustrative; the catchments of BMPFast sample project Detention Multiple catchments 2020 Manual pages 190 196) |
| Area, pre / post | 37.41 / 37.41 ac | Site (illustrative; the catchments of BMPFast sample project Detention Multiple catchments 2020 Manual pages 190 196) |
| Non-DCIA curve number, pre / post | 68.3 / 84 | Site (illustrative; the catchments of BMPFast sample project Detention Multiple catchments 2020 Manual pages 190 196) |
| DCIA, pre / post | 0 / 19 % | Site (illustrative; the catchments of BMPFast sample project Detention Multiple catchments 2020 Manual pages 190 196) |
| EMC TN, pre / post | 2.110 / 1.816 mg/L | BMPFast land use table (AH Vol I Table 9.2) |
| EMC TP, pre / post | 0.180 / 0.453 mg/L | BMPFast land use table (AH Vol I Table 9.2) |
| Treatments (one in each catchment) | ||
| Upstream subdivision | Surface Discharge Filter, treatment depth 0.50 in, media B&G CTS12 | Design (illustrative) |
| Middle subdivision | Surface Discharge Filter, treatment depth 0.50 in, media B&G CTS12 | Design (illustrative) |
| Downstream commercial | Surface Discharge Filter, treatment depth 0.50 in, media B&G CTS12 | Design (illustrative) |
Find: the removal of the site by each method, side by side, and which method BMPFast (v1) uses.
2Steps in BMPFast 2
Start BMPFast 2 and choose File ▸ New project. The tree on the left opens on the project (General Site Information). On its Entry tab enter: Project name Surface discharge filters routed in series; Meteorological zone Florida Zone 4; Mean annual rainfall 52.00 in; Type of analysis All sites non-exempted; Conduct groundwater discharge analysis Yes. (To follow along with the finished project instead, choose File ▸ Open and open
routing-filters-in-series.bmpffrom Files below.)
General Site Information: the project’s Entry tab. Press Add Catchment (left). Select the new catchment in the tree; on its Entry tab type the name Upstream subdivision and enter: Land use (pre) Agricultural - Citrus; Land use (post) User Defined Values; Area (pre) 20.75 ac; Area (post) 20.75 ac; Non-DCIA curve number (pre) 68.30; Non-DCIA curve number (post) 76.12; DCIA (post) 17.90 %; Nitrogen EMC (post) 1.816 mg/L; Phosphorus EMC (post) 0.453 mg/L. Leave the other boxes as they are (0 or blank). BMPFast 2 calculates as you type; scroll down to Calculated for the results after development: Annual runoff coefficient (ROC) (post) 0.232; Runoff volume (post) 20.871 ac-ft/yr; Nitrogen load (post) 46.733 kg/yr; Phosphorus load (post) 11.658 kg/yr.

The catchment Upstream subdivision: its Entry tab. With Upstream subdivision selected, press Add Treatment and choose Surface Discharge Filter. On its Entry tab type the Treatment name Surface Discharge Filter (BMPFast 2 starts it as “Surface Discharge Filter 1”) and enter: Treatment depth 0.50 in; Media mix B&G CTS12; Is the media design residence time more than 2 hours? Yes; Media nitrogen reduction 60.00 %; Media phosphorus reduction 90.00 %. The results are calculated as you type: Hydraulic capture 65.37 %; Nitrogen removal provided 39.22 %; Phosphorus removal provided 58.83 %.

The treatment Surface Discharge Filter: its Entry tab. Open the treatment’s Report tab: its inputs and removal in this catchment, as a report to print or save.

The treatment Surface Discharge Filter: its Report tab. Press Add Catchment (left). Select the new catchment in the tree; on its Entry tab type the name Middle subdivision and enter: Land use (pre) Agricultural - Citrus; Land use (post) User Defined Values; Area (pre) 25.13 ac; Area (post) 25.13 ac; Non-DCIA curve number (pre) 68.30; Non-DCIA curve number (post) 76.12; DCIA (post) 17.80 %; Nitrogen EMC (post) 1.715 mg/L; Phosphorus EMC (post) 0.407 mg/L. Leave the other boxes as they are (0 or blank). BMPFast 2 calculates as you type; scroll down to Calculated for the results after development: Annual runoff coefficient (ROC) (post) 0.231; Runoff volume (post) 25.199 ac-ft/yr; Nitrogen load (post) 53.286 kg/yr; Phosphorus load (post) 12.646 kg/yr.

The catchment Middle subdivision: its Entry tab. With Middle subdivision selected, press Add Treatment and choose Surface Discharge Filter. On its Entry tab type the Treatment name Surface Discharge Filter (BMPFast 2 starts it as “Surface Discharge Filter 1”) and enter: Treatment depth 0.50 in; Media mix B&G CTS12; Is the media design residence time more than 2 hours? Yes; Media nitrogen reduction 60.00 %; Media phosphorus reduction 90.00 %. The results are calculated as you type: Hydraulic capture 65.35 %; Nitrogen removal provided 39.21 %; Phosphorus removal provided 58.82 %. These are the treatment alone, on its own catchment’s runoff; the routing calculates it again with the water that drains to it from upstream, so the routing’s numbers below differ.

The treatment Surface Discharge Filter: its Entry tab. Open the treatment’s Report tab: its inputs and removal in this catchment, as a report to print or save.

The treatment Surface Discharge Filter: its Report tab. Press Add Catchment (left). Select the new catchment in the tree; on its Entry tab type the name Downstream commercial and enter: Land use (pre) Agricultural - Citrus; Land use (post) User Defined Values; Area (pre) 37.41 ac; Area (post) 37.41 ac; Non-DCIA curve number (pre) 68.30; Non-DCIA curve number (post) 84.00; DCIA (post) 19.00 %; Nitrogen EMC (post) 1.816 mg/L; Phosphorus EMC (post) 0.453 mg/L. Leave the other boxes as they are (0 or blank). BMPFast 2 calculates as you type; scroll down to Calculated for the results after development: Annual runoff coefficient (ROC) (post) 0.295; Runoff volume (post) 47.842 ac-ft/yr; Nitrogen load (post) 107.124 kg/yr; Phosphorus load (post) 26.722 kg/yr.

The catchment Downstream commercial: its Entry tab. With Downstream commercial selected, press Add Treatment and choose Surface Discharge Filter. On its Entry tab type the Treatment name Surface Discharge Filter (BMPFast 2 starts it as “Surface Discharge Filter 1”) and enter: Treatment depth 0.50 in; Media mix B&G CTS12; Is the media design residence time more than 2 hours? Yes; Media nitrogen reduction 60.00 %; Media phosphorus reduction 90.00 %. The results are calculated as you type: Hydraulic capture 58.30 %; Nitrogen removal provided 34.98 %; Phosphorus removal provided 52.47 %. These are the treatment alone, on its own catchment’s runoff; the routing calculates it again with the water that drains to it from upstream, so the routing’s numbers below differ.

The treatment Surface Discharge Filter: its Entry tab. Open the treatment’s Report tab: its inputs and removal in this catchment, as a report to print or save.

The treatment Surface Discharge Filter: its Report tab. Press Add Routing (left). BMPFast 2 adds Routing 1 under Catchment Routings, with every catchment draining to the outlet and no treatment; a project can have several routings, compared side by side. On its Entry tab (How the routing is calculated Strand routing (v1's routing; use this for permits); Surface discharge filters in series Handbook equation (each filter on its own; v1's method)) set each catchment as in this table:
Catchment Drains to Treatment used Runoff from upstream catchments Upstream subdivision Middle subdivision Surface Discharge Filter Middle subdivision Downstream commercial Surface Discharge Filter Treated with this catchment's own runoff Downstream commercial Outlet Surface Discharge Filter Treated with this catchment's own runoff A catchment is treated only by the treatment its routing uses.

The routing’s Entry tab: where each catchment drains and the treatment it uses. Open the routing’s Report tab. Results shows the loads leaving the site, the removal provided and required, and whether the performance standard is met; the list at the top of the tab has v1’s reports for the same routing (Summary, Complete, Flow Balance, AH Vol I Sec 9 compliance).

The routing’s Report tab: Results. Select Routing 1 in the tree and press Add Routing: BMPFast 2 adds Routing 2, a copy of Routing 1 (every catchment drains and is treated the same way). On its Entry tab choose Surface discharge filters in series: Equivalent treatment depth (the filters as one retention). That is the only difference between the routings.

Routing 2 (Equivalent treatment depth): its Entry tab. Open Routing 2’s Report tab: Results for this method.

Routing 2 (Equivalent treatment depth): its Report tab, Results. With two routings or more, Compare routings appears at the end of Catchment Routings. Select it and open its Report tab: the routings side by side, the loads leaving the site and the removal by each method.

Compare routings: its Report tab, the routings side by side. Its Plots tab draws the same comparison as charts. Save the project with File ▸ Save; compare it with the .bmpf under Files.

Compare routings: its Plots tab.
3Results
| Routing (method) | Leaving the site; removal | Performance standard met? |
|---|---|---|
| Routing 1: Handbook equation | N 101.944 / P 16.117 kg/yr; removal N 50.79 % / P 68.41 % | No: N short (50.8 of 70.4 %); P short (68.4 of 89.8 %) |
| Routing 2: Equivalent treatment depth | N 70.069 / P 9.408 kg/yr; removal N 66.17 % / P 81.56 % | No: N short (66.2 of 70.4 %); P short (81.6 of 89.8 %) |
| Catchment | Its treatment, alone |
|---|---|
| Upstream subdivision | Treatment depth 0.500 in, B&G CTS12: capture 65.37 %, removal N 39.22 % / P 58.83 % |
| Middle subdivision | Treatment depth 0.500 in, B&G CTS12: capture 65.35 %, removal N 39.21 % / P 58.82 % |
| Downstream commercial | Treatment depth 0.500 in, B&G CTS12: capture 58.30 %, removal N 34.98 % / P 52.47 % |
Compare routings (Report tab)
Open this report on its own page.
Routing 2: Results
Open this report on its own page.
BMPFast 2 and BMPFast (v1)
BMPFast (v1) has the same choice since October 20, 2026, under the diagram on its Catchment Configuration window, with the Handbook equation as the default: its numbers are Routing 1's, and with Equivalent Treatment Depth chosen, Routing 2's.
4Check
Handbook equation (Routing 1). Each filter removes its own share (capture at its treatment depth × the media’s removal) of what reaches it, and the loads are chained: Equation 9-5 of the Applicant’s Handbook.
Equivalent treatment depth (Routing 2). Each filter’s own removal is turned into the treatment depth at which the retention curves give that removal, for nitrogen and phosphorus separately:
| Catchment | Equivalent depth, N | Equivalent depth, P |
|---|---|---|
| Upstream subdivision | 0.197 in | 0.395 in |
| Middle subdivision | 0.197 in | 0.395 in |
| Downstream commercial | 0.209 in | 0.412 in |
Added: N 0.603 in, P 1.202 in. The curves at those depths, with the area-weighted CN 79.66 and DCIA 18.36 %, give N 66.17 % and P 81.56 %; BMPFast 2: 66.17 % / 81.56 % agrees. This method is not in the Handbook: say in a submittal which one was used. Comparison of Methods for Calculating Filters in Series works both by hand.
5Files
- routing-filters-in-series.bmpf: the project, saved by BMPFast 2. Save it (your browser puts it in Downloads), then in BMPFast 2 choose File ▸ Open and open it. Opened again and calculated, it gives the numbers on this page.
- Routing 1 (BMPFast 2’s report, as Open in browser on its Report tab gives it)
- Routing 1 — Summary Report (BMPFast 2’s report, as Open in browser on its Report tab gives it)
- Surface Discharge Filter (Upstream subdivision) (BMPFast 2’s report, as Open in browser on its Report tab gives it)
- Surface Discharge Filter — calculations (Upstream subdivision) (BMPFast 2’s report, as Open in browser on its Report tab gives it)
- Surface Discharge Filter (Middle subdivision) (BMPFast 2’s report, as Open in browser on its Report tab gives it)
- Surface Discharge Filter — calculations (Middle subdivision) (BMPFast 2’s report, as Open in browser on its Report tab gives it)
- Surface Discharge Filter (Downstream commercial) (BMPFast 2’s report, as Open in browser on its Report tab gives it)
- Surface Discharge Filter — calculations (Downstream commercial) (BMPFast 2’s report, as Open in browser on its Report tab gives it)
- Routing 1 (Upstream subdivision) (BMPFast 2’s report, as Open in browser on its Report tab gives it)
- Routing 2 (Middle subdivision) (BMPFast 2’s report, as Open in browser on its Report tab gives it)
- Compare routings (BMPFast 2’s report, as Open in browser on its Report tab gives it)
6Help and methodology
Calculated with BMPFast 2 version 2.0.0 (2026-10-20), a problem of BMPFast 2’s own. Screen captures are of BMPFast 2’s own window and are for demonstration only.