SoftwarePlus.ai

All programs › BMPFast › BMPFast 2 sample problems

Retention efficiency from the tables: Zone 2, 1.2 in

CN 75, DCIA 25 %, 1.2 in in Zone 2, against the worksheet.

1The problem

A 10-acre subdivision in Zone 2 (CN 75, DCIA 25 %). Read the capture of a 1.2-inch treatment depth from the tables, then check it on the Retention worksheet.

InputValueSource
Project (General Site Information)
Meteorological zoneFlorida Zone 2Zone map (help page 815)
Mean annual rainfall50 inMean annual rainfall map (help page 815)
Performance standard (analysis type)BMP AnalysisSite (illustrative)
Catchment 1: Subdivision (Watershed Characteristics)
Land use, pre / postAgricultural - Pasture / Single-FamilySite (illustrative)
Area, pre / post10 / 10 acSite (illustrative)
Non-DCIA curve number, pre / post61 / 75Site (illustrative)
DCIA, pre / post0 / 25 %Site (illustrative)
EMC TN, pre / post3.030 / 1.770 mg/LBMPFast land use table (AH Vol I Table 9.2)
EMC TP, pre / post0.593 / 0.327 mg/LBMPFast land use table (AH Vol I Table 9.2)

Find: the capture efficiency from the tables, and the same value from the Retention worksheet.

2Steps in BMPFast 2

  1. Start BMPFast 2 and choose File ▸ New project. The tree on the left opens on the project (General Site Information). On its Entry tab enter: Project name Retention efficiency lookup: Zone 2; Meteorological zone Florida Zone 2; Mean annual rainfall 50.00 in; Type of analysis BMP Analysis. (To follow along with the finished project instead, choose File ▸ Open and open lookup-table-zone2.bmpf from Files below.)

    General Site Information: the project’s Entry tab.
    General Site Information: the project’s Entry tab.
  2. In the tree open Calculators and select Retention Efficiency Tables. On its Entry tab choose the Rainfall zone Florida Zone 2, type 1.2 in Treatment depth, 75 in Non-DCIA curve number and 25 in DCIA, then press Find the efficiency beside Retention efficiency. BMPFast 2 says: “Retention efficiency 88.4 % at 1.20 in, curve number 75.0, DCIA 25.0 %.” Between the tabulated depths it interpolates; the Report tab shows the table it read.

    Retention Efficiency Tables: the efficiency found from the zone, depth, curve number and DCIA.
    Retention Efficiency Tables: the efficiency found from the zone, depth, curve number and DCIA.
  3. Press Add Catchment (left). Select the new catchment in the tree; on its Entry tab type the name Subdivision and enter: Land use (pre) Agricultural - Pasture; Land use (post) Single-Family; Area (pre) 10.00 ac; Area (post) 10.00 ac; Non-DCIA curve number (pre) 61.00; Non-DCIA curve number (post) 75.00; DCIA (post) 25.00 %. Leave the other boxes as they are (0 or blank). BMPFast 2 calculates as you type; scroll down to Calculated for the results after development: Annual runoff coefficient (ROC) (post) 0.262; Runoff volume (post) 10.917 ac-ft/yr; Nitrogen load (post) 23.825 kg/yr; Phosphorus load (post) 4.402 kg/yr.

    The catchment Subdivision: its Entry tab.
    The catchment Subdivision: its Entry tab.
  4. With Subdivision selected, press Add Treatment and choose Retention. On its Entry tab type the Treatment name Retention (BMPFast 2 starts it as “Retention 1”) and enter: Provided retention volume 1.000 ac-ft; Time to recover the design volume 72.00 hr. The results are calculated as you type: Treatment depth 1.200 in; Nitrogen removal provided 88.40 %; Phosphorus removal provided 88.40 %. (A volume of 1 ac-ft over the catchment is a treatment depth of 1.200 in: the depth looked up above.)

    The treatment Retention: its Entry tab.
    The treatment Retention: its Entry tab.
  5. Open the treatment’s Report tab: its inputs and removal, as a report to print or save.

    The treatment Retention: its Report tab.
    The treatment Retention: its Report tab.
  6. Press Add Routing (left). BMPFast 2 adds Routing 1 under Catchment Routings, with every catchment draining to the outlet and no treatment; a project can have several routings, compared side by side. On its Entry tab (How the routing is calculated Strand routing (v1's routing; use this for permits)) set each catchment as in this table:

    CatchmentDrains toTreatment used
    SubdivisionOutletRetention

    A catchment is treated only by the treatment its routing uses.

    The routing’s Entry tab: where each catchment drains and the treatment it uses.
    The routing’s Entry tab: where each catchment drains and the treatment it uses.
  7. Open the routing’s Report tab. Results shows the loads leaving the site, the removal provided and required, and whether the performance standard is met; the list at the top of the tab has v1’s reports for the same routing (Summary, Complete, Flow Balance, AH Vol I Sec 9 compliance). Save the project with File ▸ Save; compare it with the .bmpf under Files.

    The routing’s Report tab: Results.
    The routing’s Report tab: Results.

3Results

The calculator

On the screenValue
Rainfall zoneFlorida Zone 2
Treatment depth1.20 in
Non-DCIA curve number75.0
DCIA25.0 %
Retention efficiency88.4 %
ResultValue
Efficiency from the tables88.40 %
Retention treatment: treatment depth1.200 in
Retention treatment: capture88.40 %

The table the calculator read

Open this report on its own page.

BMPFast 2 and BMPFast (v1)

ResultBMPFast 2BMPFast (v1), its page
Nitrogen leaving the site2.764 kg/yr2.764 kg/yrsame
Phosphorus leaving the site0.511 kg/yr0.511 kg/yrsame
Site removal, nitrogen88.400 %88.400 %same
Site removal, phosphorus88.400 %88.400 %same
Subdivision: Retention removal, nitrogen88.400 %88.400 %same
Subdivision: Retention removal, phosphorus88.400 %88.400 %same

Every number BMPFast 2 gives for this problem is the same as BMPFast (v1)’s, to three decimals.

4Check

Same tables, same answer. The calculator gives 88.40 % and the Retention treatment, at 1.200 in, gives 88.40 % — the same. Between two tabulated depths BMPFast interpolates linearly; between curve number rows and DCIA columns it interpolates too (AH Vol I Appendix O; help page 4325).

5Files

  • lookup-table-zone2.bmpf: the project, saved by BMPFast 2. Save it (your browser puts it in Downloads), then in BMPFast 2 choose File ▸ Open and open it. Opened again and calculated, it gives the numbers on this page.
  • lookup-table-zone2.bmpt: the same project as BMPFast (v1) saved it. BMPFast 2 opens it too (File ▸ Open); saving it then makes a .bmpf and leaves the .bmpt as it was.
  • Routing 1 (BMPFast 2’s report, as Open in browser on its Report tab gives it)
  • Routing 1 — Summary Report (BMPFast 2’s report, as Open in browser on its Report tab gives it)
  • Retention (BMPFast 2’s report, as Open in browser on its Report tab gives it)
  • Retention — calculations (BMPFast 2’s report, as Open in browser on its Report tab gives it)
  • Retention Efficiency Tables (BMPFast 2’s report, as Open in browser on its Report tab gives it)

6Help and methodology

Calculated with BMPFast 2 version 2.0.0 (2026-10-20), which opens the problem’s v1 project as it is. Screen captures are of BMPFast 2’s own window and are for demonstration only.