SoftwarePlus.ai

All programs › BMPFast › BMPFast 2 sample problems

Media mix: a filter with and without media

Surface discharge filter, no media against B&G CTS12.

1The problem

A 5-acre subdivision is treated by a surface discharge filter with a 0.5-inch treatment depth. Compare the filter with no media chosen and with B&G CTS12.

InputValueSource
Project (General Site Information)
Meteorological zoneFlorida Zone 2Zone map (help page 815)
Mean annual rainfall50 inMean annual rainfall map (help page 815)
Performance standard (analysis type)BMP AnalysisSite (illustrative)
Catchment 1: Subdivision (Watershed Characteristics)
Land use, pre / postAgricultural - Pasture / Single-FamilySite (illustrative)
Area, pre / post5 / 5 acSite (illustrative)
Non-DCIA curve number, pre / post61 / 75Site (illustrative)
DCIA, pre / post0 / 25 %Site (illustrative)
EMC TN, pre / post3.030 / 1.770 mg/LBMPFast land use table (AH Vol I Table 9.2)
EMC TP, pre / post0.593 / 0.327 mg/LBMPFast land use table (AH Vol I Table 9.2)
Filter treatment depth0.5 inDesign (illustrative)

Find: the filter’s TN and TP removal with no media and with B&G CTS12.

2Steps in BMPFast 2

  1. Start BMPFast 2 and choose File ▸ New project. The tree on the left opens on the project (General Site Information). On its Entry tab enter: Project name Media mix: surface discharge filter, none vs B&G CTS12; Meteorological zone Florida Zone 2; Mean annual rainfall 50.00 in; Type of analysis BMP Analysis; Conduct groundwater discharge analysis Yes. (To follow along with the finished project instead, choose File ▸ Open and open media-mix-filter.bmpf from Files below.)

    General Site Information: the project’s Entry tab.
    General Site Information: the project’s Entry tab.
  2. Press Add Catchment (left). Select the new catchment in the tree; on its Entry tab type the name Subdivision and enter: Land use (pre) Agricultural - Pasture; Land use (post) Single-Family; Area (pre) 5.00 ac; Area (post) 5.00 ac; Non-DCIA curve number (pre) 61.00; Non-DCIA curve number (post) 75.00; DCIA (post) 25.00 %. Leave the other boxes as they are (0 or blank). BMPFast 2 calculates as you type; scroll down to Calculated for the results after development: Annual runoff coefficient (ROC) (post) 0.262; Runoff volume (post) 5.458 ac-ft/yr; Nitrogen load (post) 11.912 kg/yr; Phosphorus load (post) 2.201 kg/yr.

    The catchment Subdivision: its Entry tab.
    The catchment Subdivision: its Entry tab.
  3. With Subdivision selected, press Add Treatment and choose Surface Discharge Filter. On its Entry tab type the Treatment name Surface Discharge Filter, then choose the Media mix first: the Treatment depth box stays locked until a mix is chosen (“Choose a filter media below first”). Choose B&G CTS12: BMPFast 2 fills in its Media nitrogen reduction 60 % and phosphorus reduction 90 % (residence time more than 2 hours: Yes). Now type the Treatment depth 0.50 in. The removal is capture × media: Hydraulic capture 71.50 %, Nitrogen removal provided 42.90 %, Phosphorus 64.35 %. (Choosing a mix also turns on the project’s groundwater analysis on General Site Information, as v1 does. The list of mixes, with any of your own, is Project ▸ Media mix library.)

    The treatment Surface Discharge Filter: its Entry tab.
    The treatment Surface Discharge Filter: its Entry tab.
  4. Now the same filter with no media. Right-click Surface Discharge Filter in the tree and choose Copy treatment (also on the Project menu): a catchment can hold any number of treatments of one type, so the two cases sit side by side. On the copy’s Entry tab name it Surface Discharge Filter, no media and set Media mix to Not Specified. The Treatment depth stays at 0.50 in (shown greyed, since no mix is chosen) and the capture is the same, 71.50 %, but with no media the filter is credited with no removal: Nitrogen and Phosphorus removal provided 0.00 % and 0.00 %. The routing below uses Surface Discharge Filter.

    The treatment Surface Discharge Filter, no media: its Entry tab.
    The treatment Surface Discharge Filter, no media: its Entry tab.
  5. Open the treatment’s Report tab: its inputs and removal, as a report to print or save.

    The treatment Surface Discharge Filter: its Report tab.
    The treatment Surface Discharge Filter: its Report tab.
  6. Press Add Routing (left). BMPFast 2 adds Routing 1 under Catchment Routings, with every catchment draining to the outlet and no treatment; a project can have several routings, compared side by side. On its Entry tab (How the routing is calculated Strand routing (v1's routing; use this for permits)) set each catchment as in this table:

    CatchmentDrains toTreatment used
    SubdivisionOutletSurface Discharge Filter

    A catchment is treated only by the treatment its routing uses.

    The routing’s Entry tab: where each catchment drains and the treatment it uses.
    The routing’s Entry tab: where each catchment drains and the treatment it uses.
  7. Open the routing’s Report tab. Results shows the loads leaving the site, the removal provided and required, and whether the performance standard is met; the list at the top of the tab has v1’s reports for the same routing (Summary, Complete, Flow Balance, AH Vol I Sec 9 compliance). Save the project with File ▸ Save; compare it with the .bmpf under Files.

    The routing’s Report tab: Results.
    The routing’s Report tab: Results.

3Results

Result (BMPFast 2)ValueBMPFast (v1)
No media (Surface Discharge Filter, no media): TN / TP removal0.00 % / 0.00 %v1: 0.00 % / 0.00 %
B&G CTS12: media reduction TN / TP60 % / 90 %
B&G CTS12 (Surface Discharge Filter): TN / TP removal42.90 % / 64.35 %
Hydraulic capture (both)71.50 %

The treatment the routing uses is the second; the table below compares its results, and the site’s, with v1’s.

BMPFast 2 and BMPFast (v1)

ResultBMPFast 2BMPFast (v1), its page
Nitrogen leaving the site6.802 kg/yr6.802 kg/yrsame
Phosphorus leaving the site0.785 kg/yr0.785 kg/yrsame
Site removal, nitrogen42.900 %42.900 %same
Site removal, phosphorus64.350 %64.350 %same
Subdivision: Filtration removal, nitrogen42.900 %42.900 %same
Subdivision: Filtration removal, phosphorus64.350 %64.350 %same

Every number BMPFast 2 gives for this problem is the same as BMPFast (v1)’s, to three decimals.

4Check

Capture. The retention efficiency tables for Florida Zone 2 at a treatment depth of 0.500 in, non-DCIA CN 75.00 and DCIA 25.0 % give a hydraulic capture of 71.50 % (AH Vol I Appendix O; read the same tables with Calculators ▸ Retention Efficiency Tables, help page 4325).

Removal.

The water captured passes through the media and leaves as surface discharge, so removal = capture × media reduction:

The media reductions are those of B&G CTS12 (Media and Filtration Methodology).

5Files

  • media-mix-filter.bmpf: the project, saved by BMPFast 2. Save it (your browser puts it in Downloads), then in BMPFast 2 choose File ▸ Open and open it. Opened again and calculated, it gives the numbers on this page.
  • media-mix-filter.bmpt: the same project as BMPFast (v1) saved it. BMPFast 2 opens it too (File ▸ Open); saving it then makes a .bmpf and leaves the .bmpt as it was.
  • Routing 1 (BMPFast 2’s report, as Open in browser on its Report tab gives it)
  • Routing 1 — Summary Report (BMPFast 2’s report, as Open in browser on its Report tab gives it)
  • Surface Discharge Filter (BMPFast 2’s report, as Open in browser on its Report tab gives it)
  • Surface Discharge Filter — calculations (BMPFast 2’s report, as Open in browser on its Report tab gives it)

6Help and methodology

Calculated with BMPFast 2 version 2.0.0 (2026-10-20), which opens the problem’s v1 project as it is. Screen captures are of BMPFast 2’s own window and are for demonstration only.