All programs › BMPFast › Sample problems
Vegetated natural buffer behind homes (retention)
A 50 ft buffer, 600 ft long; BMP Analysis, Zone 2.
Help: Vegetated Natural Buffer (help page 296) · Download the .bmpt · Link to Solution in BMPFast Version 2
1The problem
The back yards of a 2-acre row of homes (145 ft deep) drain across an undisturbed natural buffer 50 ft wide and 600 ft long that infiltrates.
| Input | Value | Source |
|---|---|---|
| Project (General Site Information) | ||
| Meteorological zone | Florida Zone 2 | Zone map (help page 815) |
| Mean annual rainfall | 50 in | Mean annual rainfall map (help page 815) |
| Performance standard (analysis type) | BMP Analysis | Site (illustrative) |
| Catchment 1: Backyards (Watershed Characteristics) | ||
| Land use, pre / post | Undeveloped - Mesic Flatwoods / Single-Family | Site (illustrative) |
| Area, pre / post | 2 / 2 ac | Site (illustrative) |
| Non-DCIA curve number, pre / post | 70 / 75 | Site (illustrative) |
| DCIA, pre / post | 0 / 20 % | Site (illustrative) |
| EMC TN, pre / post | 1.087 / 1.770 mg/L | BMPFast land use table (AH Vol I Table 9.2) |
| EMC TP, pre / post | 0.043 / 0.327 mg/L | BMPFast land use table (AH Vol I Table 9.2) |
| Vegetated Natural Buffer (worksheet) | ||
| Retention or Detention + Plants | Retention | Design (illustrative) |
| Buffer width | 50 ft | Design (illustrative) |
| Buffer length | 600 ft | Design (illustrative) |
| Storage depth | 1 ft | Design (illustrative) |
| Width of feeder area | 145 ft | Design (illustrative) |
| Soil storage capacity | 0.2 in/in | Design (illustrative) |
| Buffer width slope | 2 % | Design (illustrative) |
Find: the TN and TP removal of the BMP, the loads leaving the site, and whether the performance standard is met.
2Steps in BMPFast
Press New Project. On General Site Information (the main window; its title bar reads General Site Information and your license key) type the project name Vegetated natural buffer: retention, choose Florida Zone 2, enter 50 in of mean annual rainfall and choose the performance standard BMP Analysis.

General Site Information (the main window). Press 1. Enter Catchment. For Catchment 1 type the name Backyards, choose the land uses Undeveloped - Mesic Flatwoods (pre) and Single-Family (post), enter the areas 2 and 2 ac, the non-DCIA curve numbers 70 and 75 and the DCIA 0 and 20 %, then press Calculate. BMPFast shows the annual runoff coefficient, the runoff and the TN and TP loads. Press Back.

Watershed Characteristics Worksheet (1. Enter Catchment). Press 2. Enter Treatment and then Vegetated Buffer. On the Vegetated Natural Buffer worksheet: Retention or Detention + Plants Retention; Buffer width 50 ft; Buffer length 600 ft; Storage depth 1 ft; Width of feeder area 145 ft; Soil storage capacity 0.2 in/in; Buffer width slope 2 %. Press Calculate. The report on the worksheet shows the inputs and the results.

The BMP worksheet after Calculate: the report on the left. Press the same button again, now labelled Equations: the worksheet shows each equation with this problem’s values. Press Back to return to the treatment options.

The same worksheet showing Equations: each equation with this problem’s values. On the main window press 3. Configure Catchments and double-click Catchment 1. Choose Vegetated Natural Buffer as the BMP used in routing and the Outlet as where it goes. Press Back twice. (A catchment’s BMP is only used once it is chosen here.)

Routing for Catchment 1 (3. Configure Catchments): the BMP used and where the catchment goes. Press 4. Summary Report. The Report Viewer shows the loads, the removal and whether the performance standard is met. Press Save Project to keep your copy; compare it with the .bmpt under Files.

The Summary Report (4. Summary Report) in the Report Viewer.
3Results
| Result | Value |
|---|---|
| Catchment 1: computed by BMPFast | |
| Annual runoff coefficient (ROC), pre / post | 0.057 / 0.225 |
| Runoff, pre / post | 0.475 / 1.875 ac-ft/yr |
| TN load, pre / post | 0.637 / 4.092 kg/yr |
| TP load, pre / post | 0.025 / 0.756 kg/yr |
| Vegetated Natural Buffer: computed by BMPFast | |
| Treatment depth | 0.615 in |
| Hydraulic capture efficiency | 75.73 % |
| Provided TN / TP removal | 75.73 % / 75.73 % |
| TN load in → out | 4.092 → 0.993 kg/yr |
| TP load in → out | 0.756 → 0.183 kg/yr |
| Site (all catchments, at the outlet) | |
| TN load: catchments → outlet | 4.092 → 0.993 kg/yr |
| TP load: catchments → outlet | 0.756 → 0.183 kg/yr |
| Provided removal TN / TP | 75.7 % / 75.7 % |
The BMP report
Open this report on its own page.
The Summary Report
4Check
Runoff and loads (Equations 9-1 and 9-2 of AH Vol I).
| Runoff | = ROC × area × rainfall / 12 |
| = 0.225 × 2.00 ac × 50.0 in / 12 | |
| = 1.875 ac-ft/yr (program 1.875). |
| TN load | = EMC × runoff × 1.233 |
| = 1.770 × 1.875 × 1.233 | |
| = 4.092 kg/yr (program 4.092) |
| TP load | = 0.327 × 1.875 × 1.233 |
| = 0.756 kg/yr (program 0.756). |
1.233 kg is 1 mg/L in 1 ac-ft.
Treatment depth.
| Depth | = 12 × width × depth × soil storage / (width + feeder width) |
| = 12 × 50 × 1.00 × 0.20 / (50 + 145) | |
| = 0.6154 in (program 0.6154). |
Capture. The retention efficiency tables for Florida Zone 2 at a treatment depth of 0.615 in, non-DCIA CN 75.00 and DCIA 20.0 % give a hydraulic capture of 75.73 % (AH Vol I Appendix O; read the same tables with Tools › Retention Efficiency Lookup Tables, help page 4325). As a retention system the removal equals the capture.
Load out.
| TN out | = load in × (1 − removal) |
| = 4.092 × (1 − 75.73 / 100) | |
| = 0.993 kg/yr (program 0.993) |
| TP out | = 0.756 × (1 − 75.73 / 100) |
| = 0.183 kg/yr (program 0.183). |
The program’s Equations page
5Files
- buffer-retention.bmpt: the project, saved by BMPFast. Save it (your browser puts it in Downloads). In BMPFast press Open Project, then Open Project again in the Open BMPFast Project dialog (below its Recent Projects list), and choose the file.
- Equations page (worksheet) (as BMPFast shows it)
- Summary Report (as BMPFast shows it)
- BMP report (worksheet) (as BMPFast shows it)
6Help and methodology
Calculated with BMPFast 1.1.9 (build 6.0.0, 2026-10-16). Older versions may not have the Equations button or may give slightly different results; download the latest at bmpfast.com. Screen captures are for demonstration only.