All programs › BMPFast › Sample problems
Discovery plot: outlet phosphorus against DCIA
Example Problem 5: TP at the outlet as the directly connected impervious area grows.
Help: Discovery Plots (help page 4477) · Download the .bmpt · Link to Solution in BMPFast Version 2
1The problem
The BMPFast sample project Example Problem 5 (retention → wet pond). How does the outlet phosphorus load change as the post-development DCIA goes from 20 % to 80 %?
| Input | Value | Source |
|---|---|---|
| Project (General Site Information) | ||
| Meteorological zone | Florida Zone 5 | Zone map (help page 815) |
| Mean annual rainfall | 61 in | Mean annual rainfall map (help page 815) |
| Performance standard (analysis type) | Specified Removal Efficiency | BMPFast sample project |
| Specified removal: TN / TP | 70 % / 80 % | BMPFast sample project |
| Catchment 1: Highway Section 206 (Watershed Characteristics) | ||
| Land use, pre / post | Undeveloped - Wet Flatwoods / Highway | BMPFast sample project |
| Area, pre / post | 6 / 6 ac | BMPFast sample project |
| Non-DCIA curve number, pre / post | 80 / 80 | BMPFast sample project |
| DCIA, pre / post | 0 / 60 % | BMPFast sample project |
| EMC TN, pre / post | 1.213 / 1.250 mg/L | BMPFast land use table (AH Vol I Table 9.2) |
| EMC TP, pre / post | 0.021 / 0.173 mg/L | BMPFast land use table (AH Vol I Table 9.2) |
| Wet pond area (no loading) | 1.00 ac | BMPFast sample project |
Find: how Total Outlet Phosphorus Loading changes as Post DCIA Percent varies.
2Steps in BMPFast
Press Open Project and open
discovery-dcia.bmpt(the file under Files; it is the BMPFast sample project Example Problem 5 one catch ret + det.bmpt). General Site Information (the main window; its title bar reads General Site Information and your license key) shows Florida Zone 5, 61.0 in of rainfall and the performance standard Specified Removal Efficiency.
General Site Information (the main window). Choose the Y-Axis result Total Outlet Phosphorus Loading, tick Post DCIA Percent, type the range and the number of steps, and press Set as X-Axis. The curve is calculated by the program at each step; the project itself is not changed. Press Save Project to keep your copy; compare it with the .bmpt under Files.

The Discovery Plot.
3Results
| Post DCIA Percent | Total Outlet Phosphorus Loading |
|---|---|
| 20.000 | 0.133 |
| 28.571 | 0.164 |
| 37.143 | 0.202 |
| 45.714 | 0.247 |
| 54.286 | 0.300 |
| 62.857 | 0.359 |
| 71.429 | 0.425 |
| 80.000 | 0.498 |
4Check
The current design is on the curve. The project’s own value, X = 60.000, gives Y = 0.338: the point the window marks. Every other point is the full project recalculated with only X changed, so a point can be checked by typing that X on the worksheet or catchment form and calculating. The curve runs from 0.133 to 0.498 over the range (Discovery Plots Methodology).
5Files
- discovery-dcia.bmpt: the project, saved by BMPFast. Save it (your browser puts it in Downloads). In BMPFast press Open Project, then Open Project again in the Open BMPFast Project dialog (below its Recent Projects list), and choose the file.
- Summary Report (as BMPFast shows it)
- BMP report (worksheet) (as BMPFast shows it)
6Help and methodology
Calculated with BMPFast 1.1.9 (build 6.0.0, 2026-10-16). Older versions may not have the Equations button or may give slightly different results; download the latest at bmpfast.com. Screen captures are for demonstration only.