SoftwarePlus.ai

All programs › BMPFast › Sample problems

Discovery plot: outlet nitrogen against treatment depth

Example Problem 3: TN at the outlet for depths of 0.25 to 2 in.

1The problem

The BMPFast sample project Example Problem 3. How much does the outlet nitrogen load fall as the retention treatment depth grows from 0.25 to 2 in?

InputValueSource
Project (General Site Information)
Meteorological zoneFlorida Zone 4Zone map (help page 815)
Mean annual rainfall50 inMean annual rainfall map (help page 815)
Performance standard (analysis type)Specified Removal EfficiencyBMPFast sample project
Specified removal: TN / TP75 % / 75 %BMPFast sample project
Catchment 1: catchment 1 (Watershed Characteristics)
Land use, pre / postAgricultural - Pasture / Single-FamilyBMPFast sample project
Area, pre / post11 / 11 acBMPFast sample project
Non-DCIA curve number, pre / post50 / 65BMPFast sample project
DCIA, pre / post0 / 25 %BMPFast sample project
EMC TN, pre / post3.030 / 1.770 mg/LBMPFast land use table (AH Vol I Table 9.2)
EMC TP, pre / post0.593 / 0.327 mg/LBMPFast land use table (AH Vol I Table 9.2)

Find: how Total Outlet Nitrogen Loading changes as Treatment Depth varies.

2Steps in BMPFast

  1. Press Open Project and open discovery-retention-depth.bmpt (the file under Files; it is the BMPFast sample project Example Problem 3.bmpt). General Site Information (the main window; its title bar reads General Site Information and your license key) shows Florida Zone 4, 50.0 in of rainfall and the performance standard Specified Removal Efficiency.

    General Site Information (the main window).
    General Site Information (the main window).
  2. Press 7. Discovery Plots. The window lists the results (Y) and the design values (X) of the project.

    Discovery Plots as it opens.
    Discovery Plots as it opens.
  3. Choose the Y-Axis result Total Outlet Nitrogen Loading, tick Treatment Depth, type the range and the number of steps, and press Set as X-Axis. The curve is calculated by the program at each step; the project itself is not changed. Press Save Project to keep your copy; compare it with the .bmpt under Files.

    The Discovery Plot.
    The Discovery Plot.

3Results

Treatment DepthTotal Outlet Nitrogen Loading
0.25011.073
0.4697.133
0.6885.057
0.9063.845
1.1253.039
1.3442.455
1.5622.018
1.7811.682
2.0001.403

4Check

The current design is on the curve. The project’s own value, X = 0.552, gives Y = 6.150: the point the window marks. Every other point is the full project recalculated with only X changed, so a point can be checked by typing that X on the worksheet or catchment form and calculating. The curve runs from 11.073 to 1.403 over the range (Discovery Plots Methodology).

5Files

  • discovery-retention-depth.bmpt: the project, saved by BMPFast. Save it (your browser puts it in Downloads). In BMPFast press Open Project, then Open Project again in the Open BMPFast Project dialog (below its Recent Projects list), and choose the file.
  • Summary Report (as BMPFast shows it)
  • BMP report (worksheet) (as BMPFast shows it)

6Help and methodology

Calculated with BMPFast 1.1.9 (build 6.0.0, 2026-10-16). Older versions may not have the Equations button or may give slightly different results; download the latest at bmpfast.com. Screen captures are for demonstration only.