SoftwarePlus.ai

All programs › BMPFast › Sample problems

Sizing a filter after a wet pond

Example Problem 5: B&G CTS24 after the wet detention pond.

1The problem

The BMPFast sample project Example Problem 5: the wet detention pond is followed by a surface discharge filter with B&G CTS24 media. Size the filter for the project’s targets.

InputValueSource
Project (General Site Information)
Meteorological zoneFlorida Zone 5Zone map (help page 815)
Mean annual rainfall61 inMean annual rainfall map (help page 815)
Performance standard (analysis type)Specified Removal EfficiencyBMPFast sample project
Specified removal: TN / TP70 % / 80 %BMPFast sample project
Catchment 1: Highway Section 206 (Watershed Characteristics)
Land use, pre / postUndeveloped - Wet Flatwoods / HighwayBMPFast sample project
Area, pre / post6 / 6 acBMPFast sample project
Non-DCIA curve number, pre / post80 / 80BMPFast sample project
DCIA, pre / post0 / 60 %BMPFast sample project
EMC TN, pre / post1.213 / 1.250 mg/LBMPFast land use table (AH Vol I Table 9.2)
EMC TP, pre / post0.021 / 0.173 mg/LBMPFast land use table (AH Vol I Table 9.2)
Wet pond area (no loading)1.00 acBMPFast sample project

Find: the filter surface area that meets the removal targets with the upstream BMP, and the treatment depth it gives the filter.

2Steps in BMPFast

  1. Press Open Project and open filter-sizing-after-pond.bmpt (the file under Files; it is the BMPFast sample project Example Problem 5 one catch ret + det.bmpt). General Site Information (the main window; its title bar reads General Site Information and your license key) shows Florida Zone 5, 61.0 in of rainfall and the performance standard Specified Removal Efficiency.

    General Site Information (the main window).
    General Site Information (the main window).
  2. Open Surface Discharge Filter and press Sizing (or Tools › Surface Discharge Filter Sizing). Choose the upstream BMP and the filter media, and the targets. The chart shows the filter removal and the total removal against the filter surface area; the box opens on the area where both targets are met. Press Apply.

    Surface Discharge Filter Sizing.
    Surface Discharge Filter Sizing.
  3. The Surface Discharge Filter worksheet now has the treatment depth and media from Sizing. Press Save Project to keep your copy; compare it with the .bmpt under Files.

    The BMP worksheet after Calculate: the report on the left.
    The BMP worksheet after Calculate: the report on the left.

3Results

The Sizing window says:

  • Surface Discharge Filter Sizing Catchment: Highway Section 206 Analysis Type: Specified Removal Efficiency Required Removal N: 70% P: 80%
  • Incoming flow % of total: N 41.9%, P 74.0% (residence time 100.0 days) Captures 0.0%; discharges 6 of 6 ac to the filter
  • rate 0.052 gpm/sf
  • Treatment Depth 0.822 in
  • Filter (media) removal: N = 48.4% P = 61.2%
  • Total removal (upstream + filter): N = 70.0% P = 89.9% — meets both targets
  • Filter Surface Area at which both targets are met: 1788 sf (treatment depth 0.822 in)
ResultValue
Filter surface area (applied)1,788 sf
Area where both targets are met1,788 sf
Filter treatment depth0.822 in
Filter mediaB&G CTS24
Filter removal TN / TP (stand-alone)48.35 % / 61.25 %

4Check

Treatment depth. The filter’s depth is the volume it can filter, spread over the area that drains to it. Applied, the worksheet shows 0.822 in; the retention tables at that depth give a capture of 64.47 %, and × media 75 % / 95 % gives the filter’s own TN 48.35 % and TP 61.25 %.

Total. With the upstream BMP removing e, the total is e + f (1 − e/100), the treatment train of AH Vol I 9.5.1; the Equations button on the Sizing window shows it with these numbers (Media and Filtration Methodology).

5Files

  • filter-sizing-after-pond.bmpt: the project, saved by BMPFast. Save it (your browser puts it in Downloads). In BMPFast press Open Project, then Open Project again in the Open BMPFast Project dialog (below its Recent Projects list), and choose the file.
  • Summary Report (as BMPFast shows it)
  • BMP report (worksheet) (as BMPFast shows it)

6Help and methodology

Calculated with BMPFast 1.1.9 (build 6.0.0, 2026-10-16). Older versions may not have the Equations button or may give slightly different results; download the latest at bmpfast.com. Screen captures are for demonstration only.