SoftwarePlus.ai

All programs › BMPFast › Sample problems

Vegetated filter strip with media (detention)

A 30 ft strip with B&G CTS12 media; Impaired Water + OFW, Zone 4.

1The problem

A 2-acre highway sheds its runoff across a 30 ft filter strip, 800 ft long, built over B&G CTS12 media (detention).

InputValueSource
Project (General Site Information)
Meteorological zoneFlorida Zone 4Zone map (help page 815)
Mean annual rainfall52 inMean annual rainfall map (help page 815)
Performance standard (analysis type)Impaired Water + OFWSite (illustrative)
Catchment 1: Highway (Watershed Characteristics)
Land use, pre / postUndeveloped - Mesic Flatwoods / HighwaySite (illustrative)
Area, pre / post2 / 2 acSite (illustrative)
Non-DCIA curve number, pre / post70 / 80Site (illustrative)
DCIA, pre / post0 / 50 %Site (illustrative)
EMC TN, pre / post1.087 / 1.250 mg/LBMPFast land use table (AH Vol I Table 9.2)
EMC TP, pre / post0.043 / 0.173 mg/LBMPFast land use table (AH Vol I Table 9.2)
Media mixB&G CTS12 (TN 60 %, TP 90 %)BMPFast media table (help page 817)
Vegetated Filter Strip (worksheet)
System typeDetentionDesign (illustrative)
VFS width30 ftDesign (illustrative)
VFS length800 ftDesign (illustrative)
VFS depth2 ftDesign (illustrative)
Width of DCIA79 ftDesign (illustrative)
VFS storage capacity0.25 in/inDesign (illustrative)
VFS slope4 %Design (illustrative)

Find: the TN and TP removal of the BMP, the loads leaving the site, and whether the performance standard is met.

2Steps in BMPFast

  1. Press New Project. On General Site Information (the main window; its title bar reads General Site Information and your license key) type the project name Vegetated filter strip: detention with media, choose Florida Zone 4, enter 52 in of mean annual rainfall and choose the performance standard Impaired Water + OFW.

    General Site Information (the main window).
    General Site Information (the main window).
  2. Press 1. Enter Catchment. For Catchment 1 type the name Highway, choose the land uses Undeveloped - Mesic Flatwoods (pre) and Highway (post), enter the areas 2 and 2 ac, the non-DCIA curve numbers 70 and 80 and the DCIA 0 and 50 %, then press Calculate. BMPFast shows the annual runoff coefficient, the runoff and the TN and TP loads. Press Back.

    Watershed Characteristics Worksheet (1. Enter Catchment).
    Watershed Characteristics Worksheet (1. Enter Catchment).
  3. Press 2. Enter Treatment, then Vegetated Filter Strip, and on its worksheet press Media. Choose B&G CTS12 (TN 60 %, TP 90 % when all the runoff is treated) and press Back.

    Enter Media Mix Information (the Media button).
    Enter Media Mix Information (the Media button).
  4. Press 2. Enter Treatment and then Vegetated Filter Strip. On the Vegetated Filter Strip worksheet: System type Detention; VFS width 30 ft; VFS length 800 ft; VFS depth 2 ft; Width of DCIA 79 ft; VFS storage capacity 0.25 in/in; VFS slope 4 %. Press Calculate. The report on the worksheet shows the inputs and the results.

    The BMP worksheet after Calculate: the report on the left.
    The BMP worksheet after Calculate: the report on the left.
  5. Press the same button again, now labelled Equations: the worksheet shows each equation with this problem’s values. Press Back to return to the treatment options.

    The same worksheet showing Equations: each equation with this problem’s values.
    The same worksheet showing Equations: each equation with this problem’s values.
  6. On the main window press 3. Configure Catchments and double-click Catchment 1. Choose Vegetated Filter Strip as the BMP used in routing and the Outlet as where it goes. Press Back twice. (A catchment’s BMP is only used once it is chosen here.)

    Routing for Catchment 1 (3. Configure Catchments): the BMP used and where the catchment goes.
    Routing for Catchment 1 (3. Configure Catchments): the BMP used and where the catchment goes.
  7. Press 4. Summary Report. The Report Viewer shows the loads, the removal and whether the performance standard is met. Press Save Project to keep your copy; compare it with the .bmpt under Files.

    The Summary Report (4. Summary Report) in the Report Viewer.
    The Summary Report (4. Summary Report) in the Report Viewer.

3Results

ResultValue
Catchment 1: computed by BMPFast
Annual runoff coefficient (ROC), pre / post0.071 / 0.476
Runoff, pre / post0.615 / 4.125 ac-ft/yr
TN load, pre / post0.825 / 6.358 kg/yr
TP load, pre / post0.033 / 0.880 kg/yr
Vegetated Filter Strip: computed by BMPFast
Treatment depth1.651 in
Provided TN / TP removal75.60 % / 92.70 %
TN load in → out6.358 → 1.551 kg/yr
TP load in → out0.880 → 0.064 kg/yr
Site (all catchments, at the outlet)
TN load: catchments → outlet6.358 → 1.551 kg/yr
TP load: catchments → outlet0.880 → 0.064 kg/yr
Provided removal TN / TP75.6 % / 92.7 %
Required removal TN / TP (Maximum % Removal)95.0 % (not met) / 96.3 % (not met)

The BMP report

Open this report on its own page.

The Summary Report

Open this report on its own page.

4Check

Runoff and loads (Equations 9-1 and 9-2 of AH Vol I).

1.233 kg is 1 mg/L in 1 ac-ft.

Removal.

The buffer tables at a slope of 4 % and a width of 30 ft give TN 39 % and TP 27 %. The media then treat what is left:

Load out.

The standard is not met, and that is expected. “Impaired Water + OFW” requires 95 % TN and 95 % TP, and post not above pre, where the HUC 12 has both an impaired water and an OFW (AH Vol I 8.3.4(a)). The post = pre removal (Equation 9-3, (post load − pre load) / post load) is TN 87.0 % and TP 96.3 %. BMPFast takes the larger of the standard’s percentage and the post = pre removal as the Maximum % Removal, shown on every worksheet’s status bar and in the Summary Report: here TN 95.0 % and TP 96.3 %. This problem shows what this design removes (75.6 % / 92.7 %), which is less. To meet it, add BMPs in series or downstream catchments (see BMPs in Series and Routing), or size the BMP (see Sizing).

The program’s Equations page

Open this report on its own page.

5Files

6Help and methodology

Calculated with BMPFast 1.1.9 (build 6.0.0, 2026-10-16). Older versions may not have the Equations button or may give slightly different results; download the latest at bmpfast.com. Screen captures are for demonstration only.