SoftwarePlus.ai

All programs › BMPFast › Sample problems

Media mix: residence time under and over 2 hours

SAT media in a detention rain garden.

1The problem

A detention rain garden in a half-acre parking lot uses SAT media. The media removal depends on whether the water stays in the media more than 2 hours.

InputValueSource
Project (General Site Information)
Meteorological zoneFlorida Zone 2Zone map (help page 815)
Mean annual rainfall50 inMean annual rainfall map (help page 815)
Performance standard (analysis type)BMP AnalysisSite (illustrative)
Catchment 1: Parking lot (Watershed Characteristics)
Land use, pre / postUndeveloped - Mesic Flatwoods / Low-Intensity CommercialSite (illustrative)
Area, pre / post0.5 / 0.5 acSite (illustrative)
Non-DCIA curve number, pre / post70 / 80Site (illustrative)
DCIA, pre / post0 / 80 %Site (illustrative)
EMC TN, pre / post1.087 / 0.930 mg/LBMPFast land use table (AH Vol I Table 9.2)
EMC TP, pre / post0.043 / 0.190 mg/LBMPFast land use table (AH Vol I Table 9.2)
Rain gardendetention; void 0.3; 1,200 cf soil; 600 cf above mediaDesign (illustrative)

Find: the media reduction and the rain garden removal for a residence time under and over 2 hours.

2Steps in BMPFast

  1. Open Rain Garden, press Media, choose SAT and answer No to “more than 2 hours?”. Press Back.

    Media window: residence time under 2 hours.
    Media window: residence time under 2 hours.
  2. Calculate the rain garden: the removal for the short residence time.

    The worksheet with the short residence time.
    The worksheet with the short residence time.
  3. Open Media again and answer Yes.

    Enter Media Mix Information (the Media button).
    Enter Media Mix Information (the Media button).
  4. Calculate again: the removal for a residence time over 2 hours.

    The BMP worksheet after Calculate: the report on the left.
    The BMP worksheet after Calculate: the report on the left.
  5. On the main window press 3. Configure Catchments and double-click Catchment 1. Choose Rain Garden as the BMP used in routing and the Outlet as where it goes. Press Back twice. (A catchment’s BMP is only used once it is chosen here.) Press Save Project to keep your copy; compare it with the .bmpt under Files.

    Routing for Catchment 1 (3. Configure Catchments): the BMP used and where the catchment goes.
    Routing for Catchment 1 (3. Configure Catchments): the BMP used and where the catchment goes.

3Results

ResultValue
Under 2 h: media reduction TN / TP25 % / 25 %
Under 2 h: rain garden removal TN / TP25.00 % / 25.00 %
Over 2 h: media reduction TN / TP30 % / 45 %
Over 2 h: rain garden removal TN / TP30.00 % / 45.00 %

4Check

Storage.

Treatment depth.

Removal. A detention rain garden discharges what it filters, so its removal is the media reduction of SAT: TN 30 %, TP 45 % (program 30.00 / 45.00).

5Files

  • media-mix-residence-time.bmpt: the project, saved by BMPFast. Save it (your browser puts it in Downloads). In BMPFast press Open Project, then Open Project again in the Open BMPFast Project dialog (below its Recent Projects list), and choose the file.
  • Summary Report (as BMPFast shows it)
  • BMP report (worksheet) (as BMPFast shows it)

6Help and methodology

Calculated with BMPFast 1.1.9 (build 6.0.0, 2026-10-16). Older versions may not have the Equations button or may give slightly different results; download the latest at bmpfast.com. Screen captures are for demonstration only.