SoftwarePlus.ai

All programs › BMPFast › Sample problems

Service life of a B&G CTS24 filter

Example Problem 5: 2,175 sf of B&G CTS24, 24 in deep.

1The problem

The BMPFast sample project Example Problem 5: a surface discharge filter of 2,175 sf with 24 in of B&G CTS24 media, after the retention basin.

InputValueSource
Project (General Site Information)
Meteorological zoneFlorida Zone 5Zone map (help page 815)
Mean annual rainfall61 inMean annual rainfall map (help page 815)
Performance standard (analysis type)Specified Removal EfficiencyBMPFast sample project
Specified removal: TN / TP70 % / 80 %BMPFast sample project
Catchment 1: Highway Section 206 (Watershed Characteristics)
Land use, pre / postUndeveloped - Wet Flatwoods / HighwayBMPFast sample project
Area, pre / post6 / 6 acBMPFast sample project
Non-DCIA curve number, pre / post80 / 80BMPFast sample project
DCIA, pre / post0 / 60 %BMPFast sample project
EMC TN, pre / post1.213 / 1.250 mg/LBMPFast land use table (AH Vol I Table 9.2)
EMC TP, pre / post0.021 / 0.173 mg/LBMPFast land use table (AH Vol I Table 9.2)
Wet pond area (no loading)1.00 acBMPFast sample project

Find: how many years the filter media last before their phosphorus capacity is used up.

2Steps in BMPFast

  1. Press Open Project and open service-life-cts24.bmpt (the file under Files; it is the BMPFast sample project Example Problem 5 one catch ret + det.bmpt). General Site Information (the main window; its title bar reads General Site Information and your license key) shows Florida Zone 5, 61.0 in of rainfall and the performance standard Specified Removal Efficiency.

    General Site Information (the main window).
    General Site Information (the main window).
  2. Open Tools › Media Filter Service Life (or the filter worksheet). Choose the upstream BMP and the media, type the media layer depth and the filter surface area. The window shows the TP load reaching the filter, the media volume, and the service life; the chart plots the life against the area. Press Save Project to keep your copy; compare it with the .bmpt under Files.

    Media Filter Service Life.
    Media Filter Service Life.

3Results

The window says:

  • Removes 62.1% of the catchment's TP; 1.123 of 2.966 kg TP/yr reaches the filter.
  • Rate 0.052 gpm/sf, sorption 0.2 mg OP/g, saturated weight 95 lb/cf, TP reduction 95%
  • OP fraction of TP (0-1):
  • Service life: 38.7 years
  • Filter TP removal 86.3%: it retains 0.968 of 1.123 kg TP/yr OP load on the media: 0.968 kg/yr
  • Media volume 4,350 cf (2,175 sf x 24 in / 12) Media capacity 37.52 kg OP
ResultValue
Filter surface area2,175 sf

4Check

Method.

The window lists each term with its value, so the division can be done by hand from the lines above; the Equations button shows the same with the media constants. A larger area gives more media and a longer life, which the chart shows (help page 369, Media and Filtration Methodology).

5Files

  • service-life-cts24.bmpt: the project, saved by BMPFast. Save it (your browser puts it in Downloads). In BMPFast press Open Project, then Open Project again in the Open BMPFast Project dialog (below its Recent Projects list), and choose the file.
  • Summary Report (as BMPFast shows it)
  • BMP report (worksheet) (as BMPFast shows it)

6Help and methodology

Calculated with BMPFast 1.1.9 (build 6.0.0, 2026-10-16). Older versions may not have the Equations button or may give slightly different results; download the latest at bmpfast.com. Screen captures are for demonstration only.