All programs › BMPFast › Sample problems
Filter area for a 20-year service life
Example Problem 3: B&G CTS12, 18 in deep, target 20 years.
Help: Media Filter Service Life (help page 369) · Download the .bmpt · Link to Solution in BMPFast Version 2
1The problem
The BMPFast sample project Example Problem 3: a filter with 18 in of B&G CTS12 after the retention basin. At 1,000 sf, how long do the media last, and what area gives 20 years?
| Input | Value | Source |
|---|---|---|
| Project (General Site Information) | ||
| Meteorological zone | Florida Zone 4 | Zone map (help page 815) |
| Mean annual rainfall | 50 in | Mean annual rainfall map (help page 815) |
| Performance standard (analysis type) | Specified Removal Efficiency | BMPFast sample project |
| Specified removal: TN / TP | 75 % / 75 % | BMPFast sample project |
| Catchment 1: catchment 1 (Watershed Characteristics) | ||
| Land use, pre / post | Agricultural - Pasture / Single-Family | BMPFast sample project |
| Area, pre / post | 11 / 11 ac | BMPFast sample project |
| Non-DCIA curve number, pre / post | 50 / 65 | BMPFast sample project |
| DCIA, pre / post | 0 / 25 % | BMPFast sample project |
| EMC TN, pre / post | 3.030 / 1.770 mg/L | BMPFast land use table (AH Vol I Table 9.2) |
| EMC TP, pre / post | 0.593 / 0.327 mg/L | BMPFast land use table (AH Vol I Table 9.2) |
Find: how many years the filter media last before their phosphorus capacity is used up.
2Steps in BMPFast
Press Open Project and open
service-life-target.bmpt(the file under Files; it is the BMPFast sample project Example Problem 3.bmpt). General Site Information (the main window; its title bar reads General Site Information and your license key) shows Florida Zone 4, 50.0 in of rainfall and the performance standard Specified Removal Efficiency.
General Site Information (the main window). Open Tools › Media Filter Service Life (or the filter worksheet). Choose the upstream BMP and the media, type the media layer depth and the filter surface area. The window shows the TP load reaching the filter, the media volume, and the service life; the chart plots the life against the area. Press Save Project to keep your copy; compare it with the .bmpt under Files.

Media Filter Service Life.
3Results
The window says:
- Removes 75.0% of the catchment's TP; 1.136 of 4.546 kg TP/yr reaches the filter.
- Rate 0.052 gpm/sf, sorption 0.2 mg OP/g, saturated weight 95 lb/cf, TP reduction 90%
- OP fraction of TP (0-1):
- Service life: 14.7 years
- Filter Surface Area for a 20-year life: 1,437 sf The current area is below the target.
- Filter TP removal 77.5%: it retains 0.881 of 1.136 kg TP/yr OP load on the media: 0.881 kg/yr
- Media volume 1,500 cf (1,000 sf x 18 in / 12) Media capacity 12.94 kg OP
| Result | Value |
|---|---|
| Filter surface area | 1,000 sf |
| Area for the target life | 1,437 sf |
4Check
Method.
| Service life (years) | = phosphorus the media can hold (media volume × the media’s TP sorption capacity) ÷ TP removed by the media each year. |
The window lists each term with its value, so the division can be done by hand from the lines above; the Equations button shows the same with the media constants. A larger area gives more media and a longer life, which the chart shows (help page 369, Media and Filtration Methodology).
5Files
- service-life-target.bmpt: the project, saved by BMPFast. Save it (your browser puts it in Downloads). In BMPFast press Open Project, then Open Project again in the Open BMPFast Project dialog (below its Recent Projects list), and choose the file.
- Summary Report (as BMPFast shows it)
- BMP report (worksheet) (as BMPFast shows it)
6Help and methodology
Calculated with BMPFast 1.1.9 (build 6.0.0, 2026-10-16). Older versions may not have the Equations button or may give slightly different results; download the latest at bmpfast.com. Screen captures are for demonstration only.