All programs › BMPFast › Sample problems
User defined BMP: alum injection
Alum treatment with 50 % TN and 90 % TP removal; Specified Removal 60 / 85 %, Zone 3.
Help: User Defined (help page 809) · Download the .bmpt · Link to Solution in BMPFast Version 2
1The problem
A 20-acre commercial area is treated by alum injection, with 50 % TN and 90 % TP removal (illustrative). The permit asks for 60 % TN and 85 % TP.
| Input | Value | Source |
|---|---|---|
| Project (General Site Information) | ||
| Meteorological zone | Florida Zone 3 | Zone map (help page 815) |
| Mean annual rainfall | 54 in | Mean annual rainfall map (help page 815) |
| Performance standard (analysis type) | Specified Removal Efficiency | Site (illustrative) |
| Specified removal: TN / TP | 60 % / 85 % | Site (illustrative) |
| Catchment 1: Commercial site (Watershed Characteristics) | ||
| Land use, pre / post | Undeveloped - Mesic Flatwoods / High-Intensity Commercial | Site (illustrative) |
| Area, pre / post | 20 / 20 ac | Site (illustrative) |
| Non-DCIA curve number, pre / post | 70 / 80 | Site (illustrative) |
| DCIA, pre / post | 0 / 70 % | Site (illustrative) |
| EMC TN, pre / post | 1.087 / 2.400 mg/L | BMPFast land use table (AH Vol I Table 9.2) |
| EMC TP, pre / post | 0.043 / 0.345 mg/L | BMPFast land use table (AH Vol I Table 9.2) |
| User Defined BMP (worksheet) | ||
| BMP name | Alum Treating | Design (illustrative) |
| Provided nitrogen treatment | 50 % | Design (illustrative) |
| Provided phosphorus treatment | 90 % | Design (illustrative) |
Find: the TN and TP removal of the BMP, the loads leaving the site, and whether the performance standard is met.
2Steps in BMPFast
Press New Project. On General Site Information (the main window; its title bar reads General Site Information and your license key) type the project name User defined BMP: alum treatment, choose Florida Zone 3, enter 54 in of mean annual rainfall and choose the performance standard Specified Removal Efficiency, with TN 60 % and TP 85 %.

General Site Information (the main window). Press 1. Enter Catchment. For Catchment 1 type the name Commercial site, choose the land uses Undeveloped - Mesic Flatwoods (pre) and High-Intensity Commercial (post), enter the areas 20 and 20 ac, the non-DCIA curve numbers 70 and 80 and the DCIA 0 and 70 %, then press Calculate. BMPFast shows the annual runoff coefficient, the runoff and the TN and TP loads. Press Back.

Watershed Characteristics Worksheet (1. Enter Catchment). Press 2. Enter Treatment and then User Defined. On the User Defined BMP worksheet: BMP name Alum Treating; Provided nitrogen treatment 50 %; Provided phosphorus treatment 90 %. Press Calculate. The report on the worksheet shows the inputs and the results.

The BMP worksheet after Calculate: the report on the left. On the main window press 3. Configure Catchments and double-click Catchment 1. Choose User Defined BMP as the BMP used in routing and the Outlet as where it goes. Press Back twice. (A catchment’s BMP is only used once it is chosen here.)

Routing for Catchment 1 (3. Configure Catchments): the BMP used and where the catchment goes. Press 4. Summary Report. The Report Viewer shows the loads, the removal and whether the performance standard is met. Press Save Project to keep your copy; compare it with the .bmpt under Files.

The Summary Report (4. Summary Report) in the Report Viewer.
3Results
| Result | Value |
|---|---|
| Catchment 1: computed by BMPFast | |
| Annual runoff coefficient (ROC), pre / post | 0.078 / 0.596 |
| Runoff, pre / post | 7.020 / 53.640 ac-ft/yr |
| TN load, pre / post | 9.409 / 158.731 kg/yr |
| TP load, pre / post | 0.372 / 22.818 kg/yr |
| User Defined BMP: computed by BMPFast | |
| Hydraulic capture efficiency | 90.00 % |
| Provided TN / TP removal | 50.00 % / 90.00 % |
| TN load in → out | 158.731 → 79.366 kg/yr |
| TP load in → out | 22.818 → 2.282 kg/yr |
| Site (all catchments, at the outlet) | |
| TN load: catchments → outlet | 158.731 → 79.366 kg/yr |
| TP load: catchments → outlet | 22.818 → 2.282 kg/yr |
| Provided removal TN / TP | 50.0 % / 90.0 % |
| Required removal TN / TP (Maximum % Removal) | 60.0 % (not met) / 85.0 % (met) |
The BMP report
Open this report on its own page.
The Summary Report
4Check
Runoff and loads (Equations 9-1 and 9-2 of AH Vol I).
| Runoff | = ROC × area × rainfall / 12 |
| = 0.596 × 20.00 ac × 54.0 in / 12 | |
| = 53.640 ac-ft/yr (program 53.640). |
| TN load | = EMC × runoff × 1.233 |
| = 2.400 × 53.640 × 1.233 | |
| = 158.731 kg/yr (program 158.731) |
| TP load | = 0.345 × 53.640 × 1.233 |
| = 22.818 kg/yr (program 22.818). |
1.233 kg is 1 mg/L in 1 ac-ft.
Removal. A user defined BMP removes the percentages entered: TN 50.0 % and TP 90.0 %. They must be backed by data the permitting agency accepts (help page 809).
Load out.
| TN out | = load in × (1 − removal) |
| = 158.731 × (1 − 50.00 / 100) | |
| = 79.366 kg/yr (program 79.366) |
| TP out | = 22.818 × (1 − 90.00 / 100) |
| = 2.282 kg/yr (program 2.282). |
The standard is not met, and that is expected. “Specified Removal Efficiency” requires the TN and TP percentages entered for the project, for example a TMDL or BMAP criterion (AH Vol I 8.3.4(b), or as the Agency directs). The post = pre removal (Equation 9-3, (post load − pre load) / post load) is TN 94.1 % and TP 98.4 %. BMPFast takes the larger of the standard’s percentage and the post = pre removal as the Maximum % Removal, shown on every worksheet’s status bar and in the Summary Report: here TN 60.0 % and TP 85.0 %. This problem shows what this design removes (50.0 % / 90.0 %), which is less. To meet it, add BMPs in series or downstream catchments (see BMPs in Series and Routing), or size the BMP (see Sizing).
5Files
- user-defined-alum.bmpt: the project, saved by BMPFast. Save it (your browser puts it in Downloads). In BMPFast press Open Project, then Open Project again in the Open BMPFast Project dialog (below its Recent Projects list), and choose the file.
- Summary Report (as BMPFast shows it)
- BMP report (worksheet) (as BMPFast shows it)
6Help and methodology
Calculated with BMPFast 1.1.9 (build 6.0.0, 2026-10-16). Older versions may not have the Equations button or may give slightly different results; download the latest at bmpfast.com. Screen captures are for demonstration only.