Wet detention for a commercial site discharging to an impaired water

A 6.0 ac-ft pool, no littoral zone; Impaired Water, Zone 3.

1The problem

A 5-acre high-intensity commercial site on former flatwoods discharges to an impaired water. Its wet pond has a 6.0 ac-ft permanent pool and no littoral zone.

InputValueSource
Project (General Site Information)
Meteorological zoneFlorida Zone 3Zone map (help page 815)
Mean annual rainfall54 inMean annual rainfall map (help page 815)
Performance standard (analysis type)Impaired WaterSite (illustrative)
Catchment 1: Commercial site (Watershed Characteristics)
Land use, pre / postUndeveloped - Mesic Flatwoods / High-Intensity CommercialSite (illustrative)
Area, pre / post5 / 5 acSite (illustrative)
Non-DCIA curve number, pre / post70 / 80Site (illustrative)
DCIA, pre / post0 / 70 %Site (illustrative)
EMC TN, pre / post1.087 / 2.400 mg/LBMPFast land use table (AH Vol I Table 9.2)
EMC TP, pre / post0.043 / 0.345 mg/LBMPFast land use table (AH Vol I Table 9.2)
Wet Detention (worksheet)
Permanent Pool Volume6.0 ac-ftDesign (illustrative)
Check if there is a littoral zoneuntickedDesign (illustrative)
Floating Wetland or other MAPs Credit0 %Design (illustrative)

Find: the TN and TP removal of the BMP, the loads leaving the site, and whether the performance standard is met.

2Steps in BMPFast

  1. Press New Project. On General Site Information (the main window; its title bar reads General Site Information and your license key) type the project name Wet detention: commercial site, impaired water, choose Florida Zone 3, enter 54 in of mean annual rainfall and choose the performance standard Impaired Water.

    General Site Information (the main window).
    General Site Information (the main window).
  2. Press 1. Enter Catchment. For Catchment 1 type the name Commercial site, choose the land uses Undeveloped - Mesic Flatwoods (pre) and High-Intensity Commercial (post), enter the areas 5 and 5 ac, the non-DCIA curve numbers 70 and 80 and the DCIA 0 and 70 %, then press Calculate. BMPFast shows the annual runoff coefficient, the runoff and the TN and TP loads. Press Back.

    Watershed Characteristics Worksheet (1. Enter Catchment).
    Watershed Characteristics Worksheet (1. Enter Catchment).
  3. Press 2. Enter Treatment and then Wet Detention. On the Wet Detention worksheet: Permanent Pool Volume 6.0 ac-ft; leave Check if there is a littoral zone unticked; Floating Wetland or other MAPs Credit 0 %. Press Calculate. The report on the worksheet shows the inputs and the results.

    The BMP worksheet after Calculate: the report on the left.
    The BMP worksheet after Calculate: the report on the left.
  4. Press the same button again, now labelled Equations: the worksheet shows each equation with this problem’s values. Press Back to return to the treatment options.

    The same worksheet showing Equations: each equation with this problem’s values.
    The same worksheet showing Equations: each equation with this problem’s values.
  5. On the main window press 3. Configure Catchments and double-click Catchment 1. Choose Wet Detention as the BMP used in routing and the Outlet as where it goes. Press Back twice. (A catchment’s BMP is only used once it is chosen here.)

    Routing for Catchment 1 (3. Configure Catchments): the BMP used and where the catchment goes.
    Routing for Catchment 1 (3. Configure Catchments): the BMP used and where the catchment goes.
  6. Press 4. Summary Report. The Report Viewer shows the loads, the removal and whether the performance standard is met. Press Save Project to keep your copy; compare it with the .bmpt under Files.

    The Summary Report (4. Summary Report) in the Report Viewer.
    The Summary Report (4. Summary Report) in the Report Viewer.

3Results

ResultValue
Catchment 1: computed by BMPFast
Annual runoff coefficient (ROC), pre / post0.078 / 0.596
Runoff, pre / post1.755 / 13.410 ac-ft/yr
TN load, pre / post2.352 / 39.683 kg/yr
TP load, pre / post0.093 / 5.704 kg/yr
Wet Detention: computed by BMPFast
Annual residence time163.3 days
Hydraulic capture efficiency70.32 %
Provided TN / TP removal38.35 % / 70.32 %
TN load in → out39.683 → 24.466 kg/yr
TP load in → out5.704 → 1.693 kg/yr
Site (all catchments, at the outlet)
TN load: catchments → outlet39.683 → 24.466 kg/yr
TP load: catchments → outlet5.704 → 1.693 kg/yr
Provided removal TN / TP38.3 % / 70.3 %
Required removal TN / TP (Maximum % Removal)94.1 % (not met) / 98.4 % (not met)

The BMP report

Open this report on its own page.

The Summary Report

Open this report on its own page.

4Check

Runoff and loads (Equations 9-1 and 9-2 of AH Vol I).

1.233 kg is 1 mg/L in 1 ac-ft.

Annual residence time.

Removal. The wet detention equations of AH Vol I Appendix O at 163.3 days, without a littoral zone, so the removal is multiplied by 0.90, give TN 38.35 % and TP 70.32 %. The worksheet’s Equations page shows each equation with these numbers; the Wet Detention Methodology explains them.

Load out.

The standard is not met, and that is expected. “Impaired Water” requires 80 % TN and 80 % TP, and the post-development load not above the pre-development load, for a discharge to an impaired water (AH Vol I 8.3.4(a)). The post = pre removal (Equation 9-3, (post load − pre load) / post load) is TN 94.1 % and TP 98.4 %. BMPFast takes the larger of the standard’s percentage and the post = pre removal as the Maximum % Removal, shown on every worksheet’s status bar and in the Summary Report: here TN 94.1 % and TP 98.4 %. This problem shows what this design removes (38.3 % / 70.3 %), which is less. To meet it, add BMPs in series or downstream catchments (see BMPs in Series and Routing), or size the BMP (see Sizing).

The program’s Equations page

Open this report on its own page.

5Files

6Help and methodology

Calculated with BMPFast 1.1.9 (build 6.0.0, 2026-10-16). Older versions may not have the Equations button or may give slightly different results; download the latest at bmpfast.com. Screen captures are for demonstration only.