All programs › BMPFast › Retention curves
Retention curves: Florida Zone 3
Mean annual removal by a retention BMP in the Florida Keys, for treatment depths from 0.25 to 4 inches.
How to use this page. The coloured surface is the share of a year's runoff that a retention BMP in Florida Zone 3 holds back (and with it the nitrogen and phosphorus), for every non-DCIA curve number and DCIA, at one treatment depth.
- Mark a design (optional): type its non-DCIA curve number and DCIA. The plot marks the point with its removal, draws dashed lines through it, and an orange line of equal removal across the surface.
- Choose the treatment depth with the slider just above the plot, or its ‹ › buttons, from 0.25 to 4 inches. The faint grey surfaces are the other depths: the higher the depth, the higher its surface.
- Turn the plot by dragging it; scroll or pinch to zoom; point at the surface to read a value. The table under the plot lists every value for the chosen depth.
Loading the plot…
The plot could not be loaded (it uses the Plotly library from cdnjs.cloudflare.com, which may be blocked here). The help page Retention methodology has the curves as charts.
Reading the plot for Florida Zone 3
Florida Zone 3 covers the Florida Keys (rain gauges at Key West and Lignumvitae Key); the zone map is on the overview.
The surface is highest at the corner nearest you, where the curve number and the DCIA are both low: a catchment that is mostly pervious and soaks up rain, with little connected pavement, produces little runoff, so a given depth holds back most of it. Towards the far corner, more of the rain runs off and the same depth holds back a smaller share. A greater depth lifts the whole surface; most of the gain comes in the first inch or so. For example, at curve number 70 and 30 % DCIA, 0.50 in of retention holds back 65.6 % of the yearly runoff here and 2.00 in holds back 88.9 %.
The tables start at 5 % DCIA; BMPFast reads a smaller DCIA at 5 %, and so does this page. Between the tabulated values it interpolates in a straight line, as BMPFast does.
Where the numbers come from
These are the tables BMPFast uses
for every BMP that retains runoff, drawn here exactly as the program reads them (BMPFast's own CalculateEfficiency wrote every value).
They come from Harper, H.H. and Baker, D.M. (2007), Evaluation of Current Stormwater Design Criteria within the State of Florida,
Appendix D (report): a continuous
simulation of each zone's rainfall record with a dry basin that recovers half its volume in 24 hours and all of it in 72. The Environmental Resource
Permit Applicant's Handbook (Appendix O) uses the same tables. How BMPFast reads between the tabulated values is explained on the help page
Retention methodology.