Surface discharge filter with B&G CTS12

A 0.5-inch treatment depth through B&G CTS12 media; BMP Analysis, Zone 2.

1The problem

A 5-acre subdivision is treated by a surface discharge filter: 0.5 in of runoff over the catchment passes through B&G CTS12 media and is discharged.

InputValueSource
Project (General Site Information)
Meteorological zoneFlorida Zone 2Zone map (help page 815)
Mean annual rainfall50 inMean annual rainfall map (help page 815)
Performance standard (analysis type)BMP AnalysisSite (illustrative)
Catchment 1: Subdivision (Watershed Characteristics)
Land use, pre / postAgricultural - Pasture / Single-FamilySite (illustrative)
Area, pre / post5 / 5 acSite (illustrative)
Non-DCIA curve number, pre / post61 / 75Site (illustrative)
DCIA, pre / post0 / 25 %Site (illustrative)
EMC TN, pre / post3.030 / 1.770 mg/LBMPFast land use table (AH Vol I Table 9.2)
EMC TP, pre / post0.593 / 0.327 mg/LBMPFast land use table (AH Vol I Table 9.2)
Media mixB&G CTS12 (TN 60 %, TP 90 %)BMPFast media table (help page 817)
Filtration System (worksheet)
Treatment Depth0.5 inDesign (illustrative)

Find: the TN and TP removal of the BMP, the loads leaving the site, and whether the performance standard is met.

2Steps in BMPFast

  1. Press New Project. On General Site Information (the main window; its title bar reads General Site Information and your license key) type the project name Surface discharge filter: B&G CTS12, choose Florida Zone 2, enter 50 in of mean annual rainfall and choose the performance standard BMP Analysis.

    General Site Information (the main window).
    General Site Information (the main window).
  2. Press 1. Enter Catchment. For Catchment 1 type the name Subdivision, choose the land uses Agricultural - Pasture (pre) and Single-Family (post), enter the areas 5 and 5 ac, the non-DCIA curve numbers 61 and 75 and the DCIA 0 and 25 %, then press Calculate. BMPFast shows the annual runoff coefficient, the runoff and the TN and TP loads. Press Back.

    Watershed Characteristics Worksheet (1. Enter Catchment).
    Watershed Characteristics Worksheet (1. Enter Catchment).
  3. Press 2. Enter Treatment, then Surface Discharge Filter, and on its worksheet press Media. Choose B&G CTS12 (TN 60 %, TP 90 % when all the runoff is treated) and press Back.

    Enter Media Mix Information (the Media button).
    Enter Media Mix Information (the Media button).
  4. Press 2. Enter Treatment and then Surface Discharge Filter. On the Filtration System worksheet: Treatment Depth 0.5 in. Press Calculate. The report on the worksheet shows the inputs and the results.

    The BMP worksheet after Calculate: the report on the left.
    The BMP worksheet after Calculate: the report on the left.
  5. Press the same button again, now labelled Equations: the worksheet shows each equation with this problem’s values. Press Back to return to the treatment options.

    The same worksheet showing Equations: each equation with this problem’s values.
    The same worksheet showing Equations: each equation with this problem’s values.
  6. On the main window press 3. Configure Catchments and double-click Catchment 1. Choose Filtration as the BMP used in routing and the Outlet as where it goes. Press Back twice. (A catchment’s BMP is only used once it is chosen here.)

    Routing for Catchment 1 (3. Configure Catchments): the BMP used and where the catchment goes.
    Routing for Catchment 1 (3. Configure Catchments): the BMP used and where the catchment goes.
  7. Press 4. Summary Report. The Report Viewer shows the loads, the removal and whether the performance standard is met. Press Save Project to keep your copy; compare it with the .bmpt under Files.

    The Summary Report (4. Summary Report) in the Report Viewer.
    The Summary Report (4. Summary Report) in the Report Viewer.

3Results

ResultValue
Catchment 1: computed by BMPFast
Annual runoff coefficient (ROC), pre / post0.032 / 0.262
Runoff, pre / post0.675 / 5.458 ac-ft/yr
TN load, pre / post2.522 / 11.912 kg/yr
TP load, pre / post0.494 / 2.201 kg/yr
Filtration: computed by BMPFast
Treatment depth0.500 in
Hydraulic capture efficiency71.50 %
Provided TN / TP removal42.90 % / 64.35 %
TN load in → out11.912 → 6.802 kg/yr
TP load in → out2.201 → 0.785 kg/yr
Site (all catchments, at the outlet)
TN load: catchments → outlet11.912 → 6.802 kg/yr
TP load: catchments → outlet2.201 → 0.785 kg/yr
Provided removal TN / TP42.9 % / 64.3 %

The BMP report

Open this report on its own page.

The Summary Report

Open this report on its own page.

4Check

Runoff and loads (Equations 9-1 and 9-2 of AH Vol I).

1.233 kg is 1 mg/L in 1 ac-ft.

Capture. The retention efficiency tables for Florida Zone 2 at a treatment depth of 0.500 in, non-DCIA CN 75.00 and DCIA 25.0 % give a hydraulic capture of 71.50 % (AH Vol I Appendix O; read the same tables with Tools › Retention Efficiency Lookup Tables, help page 4325).

Removal.

The water captured passes through the media and leaves as surface discharge, so removal = capture × media reduction:

The media reductions are those of B&G CTS12 (Media and Filtration Methodology).

Load out.

The program’s Equations page

Open this report on its own page.

5Files

6Help and methodology

Calculated with BMPFast 1.1.9 (build 6.0.0, 2026-10-16). Older versions may not have the Equations button or may give slightly different results; download the latest at bmpfast.com. Screen captures are for demonstration only.