SoftwarePlus.ai

All programs › BMPFast › Help

Sizing

A copy of the help on bmpfast.com (last changed there 2026-10-16; copied here 2026-10-21). These pages describe the windows of BMPFast (version 1). BMPFast 2 uses the same methods; its numbered buttons are the tree on the left: General Site Information, then Catchments with their Treatments, Catchment Routings and Calculators.

Sizing finds the dimensions a BMP needs to meet your nitrogen (N) and phosphorus (P) removal targets. You open it from a BMP’s worksheet. It shows the BMP’s removal against one of its dimensions, such as a retention basin’s volume or a trench’s length, marks where both targets are met, and lets you step any dimension up or down while the curve updates. When you click Apply, the values go back to the worksheet. Cancel leaves the BMP as it was.

There are two Sizing windows:

  • Sizing, for every BMP that has a Sizing button except the Surface Discharge Filter. It works with the BMP’s own dimensions.
  • Surface Discharge Filter Sizing, for the filter. It sizes the filter’s surface area for the water an upstream BMP passes on, and shows the removal of the upstream BMP and the filter together.

Sizing looks at one BMP on its own. It calculates the BMP with its own catchment’s runoff and loads, and it does not run the routing between catchments. This matches the BMP’s worksheet and its report. To see how a dimension changes the result of the whole project, including runoff routed in from other catchments, use Discovery Plots. When other catchments are routed to this catchment and its BMP treats their runoff, both Sizing windows say so in a note under the results, naming those catchments: the size found there may not meet the targets once the project is calculated, so check the project with Discovery Plots or the Summary Report before relying on it.

Opening Sizing

Click Sizing on the BMP’s worksheet. The worksheet first stores what you typed and calculates, so Sizing starts from your current design. These worksheets have a Sizing button:

WorksheetVariables you can sizePlotted first
RetentionRetention Volume (ac-ft)Retention Volume
ExfiltrationPipe Span, Pipe Rise (in); Pipe Length, Trench Length, Trench/Vault Width, Trench Depth (ft); Void RatioTrench Length
Wet DetentionWetland Efficiency Credit (%), Permanent Pool Volume (ac-ft)Permanent Pool Volume
GreenroofGreenroof Storage (in over the greenroof area, 0 to 5)Greenroof Storage
Rain Garden (Retention)Sustainable Void Fraction, Water Above Media (cf), Credit for Native Soil and Cover Crop (%), Media Volume (cf)Media Volume
Stormwater HarvestingAvailable Harvest Volume (ac-ft), Total Area Available for Irrigation (ac), Available Harvest Rate (in/week)Available Harvest Volume
Rainwater HarvestingTotal Area Available for Irrigation (sf), Available Harvest Volume (gallons), Available Harvest Rate (in/week)Available Harvest Volume
Permeable PavementPavement Surface Area (ac), Layer Scale Factor (times the layers as entered)Layer Scale Factor
SwaleAll thirteen swale dimensions: W, B, L, impervious and pervious widths, slope S, Manning’s n, infiltration rate, side slope Z, and the swale block H, Lb and number of blocksSwale Length – L
Tree Well (Retention)Depth, Length, Width (ft), Sustainable water storage capacity of the soil, Number of Similar AreasLength
Vegetated BufferBuffer Width (10-350 ft), Buffer Length, Buffer Depth, Width of Area Feeding Buffer (ft), Water storage capacity of soil (in/in), Slope of Buffer (2-6 %)Buffer Width
Vegetated Filter StripVFS Width (15-30 ft), VFS Length, VFS Depth (1-2 ft), Width of Area Feeding VFS (ft), Slope of VFS (2-6 %), Water storage capacity of soil (in/in)VFS Width
Surface Discharge FilterFilter Surface Area (sf), in its own window (below)Filter Surface Area

Surface Discharge Filter Sizing also opens from Tools (on the Treatment Options screen) ▸ Surface Discharge Filter Sizing. User Defined BMPs and BMPs in Series have no Sizing button.

Some worksheets must be set up first. If one is not, Sizing does not open; a message says what to do:

  • Greenroof: “Select a Rainfall Station before sizing a Greenroof.”
  • Rain Garden: “Sizing applies to the Retention configuration of a Rain Garden. Set System Type to Retention first.”
  • Tree Well: “Sizing applies to the Retention configuration of a Tree Well. Set Retention or Detention to Retention first.”
  • Rainwater Harvesting: “Select a Roof Type before sizing a Rainwater Harvesting system.” or “Sizing requires the “Solve for Harvest Efficiency” option.”

Sizing a BMP, step by step

  1. Check the Removal targets (%). They start at the project’s Maximum % Removal for N and P (the values in the worksheet’s bottom strip). If the project has none, they start at the BMP’s own required removal. Type new targets, use ▲ / ▼ to change them by 5 %, or click Default targets to go back.
  2. Choose the variable to plot: click its round button in the Plot column, or click its name. The chart then shows N and P removal against that variable, with every other variable held at its current value. Choose None (values only) to see just the current N and P removal against the targets, with no curve.
  3. Read the results under the targets: Current removal (green when both targets are met, red when not), and the value of the plotted variable at which both targets are met. Click Use to set the variable to that value.
  4. Change any dimension: type a value and press Enter (or leave the box), or use ▲ / ▼. The curve, the current-design line and the crossing update at once.
  5. Click Apply to keep the values and return to the worksheet, or Cancel to discard every change made here.

Applicant’s Handbook reference

Section 9.3 Determination of Required Treatment Efficiency: the required reduction is the greater of the Section 8.3 percentage and the Equation 9-3 reduction that keeps the post-development load at the predevelopment load; the project’s Maximum % Removal that the targets start at is that value.

Section 9.5 Best Management Practices (BMPs) for Stormwater Treatment: “If the maximum load is not met, the applicant shall either modify the selected BMP or incorporate additional BMPs”; Sizing is a tool for the first of these.

A BMP with nothing entered yet (every Sizing variable still 0) opens with starting values: for example a 100 ft trench, 5 ft wide and 5 ft deep, with a 24 in pipe, for Exfiltration. Sizing then sets the plotted variable to the value that meets the targets, when that is possible. A BMP with values already entered opens on those values.

The Sizing window

PartWhat it does
Plot / Variable / ValueOne row per Sizing variable, with its units. The round button picks the variable on the X-axis. The value box takes a typed number; ▲ / ▼ step it (the tooltip gives the step). A value outside the variable’s limits is set to the limit, with a note in red that it “cannot exceed” (or “cannot be less than”) that value.
Removal targets (%)The N and P targets the curve is compared with. ▲ / ▼ change them by 5 %. Default targets restores the project’s values.
Plot range (X-axis)From / To for the plotted variable. It starts on Auto range: from the variable’s lowest value to past both the current value and the value that meets the targets. Type your own range, or click Auto range to go back.
Current removalN and P removal of the BMP as it stands, and whether it meets both targets.
… at which both targets are metThe smallest value of the plotted variable at which N and P both reach their targets, or “both targets are not met anywhere in the plotted range”. Use sets the variable to it.
Treatment Depth / ARTFor a retention-type BMP, the Treatment Depth the dimensions give, in inches (over the contributing area; for Permeable Pavement, Tree Well and Greenroof the window says just “in”, since their depth is over the catchment or the greenroof); with a note when it is over 4 in, where the retention curves stop. For Wet Detention, the average residence time (ART) in days.
ChartN removal (solid) and P removal (dashed) against the plotted variable, the two target lines, a vertical line and marker at the current design, and a diamond where both targets are met. Pale stretches of the curve break a geometry rule of the BMP (for example a trench too narrow for its pipe). For the harvesting BMPs a dotted stretch is beyond the end of the REV curves, where the removal is held at the last value.

Buttons

ButtonWhat it does
HelpOpens this page (bottom left of the window).
EquationsOpens the BMP’s Equations page in the Report Viewer: how the Treatment Depth (or other design figure) and the removal are calculated from these variables, with the current values. It is the same page as the worksheet’s Equations button.
PrintPrints the chart (a Print dialog opens first).
CopyCopies the chart as a picture, to paste into a report.
ApplyKeeps the values on the BMP and returns to the worksheet, which shows them. Permeable Pavement: each layer’s thickness is multiplied by the Layer Scale Factor, so the mix of layers is kept.
CancelPuts back every value as it was when Sizing opened. Closing the window or pressing Esc does the same.

Rules and limits

  • Each variable has a lowest value, and some a highest one (for example Vegetated Filter Strip width 15-30 ft and depth 1-2 ft, slopes 2-6 %). A value outside them is set to the limit, and a note says so.
  • Some BMPs have geometry rules. Sizing refuses a value that breaks one, keeps the previous value, and says why. Exfiltration, for example: “Pipe Span requires a 6 inch clearance with each trench edge (Trench Width must be at least Pipe Span + 12 in).”
  • The retention curves stop at 4 in of Treatment Depth. A larger depth gets no more removal, and the window says “Upper limit of retention volume treatment depth is 4 inches”.
  • The worksheet’s own checks still apply after Apply. For example, a Vegetated Natural Buffer depth over 1 ft can be sized here (the starting value is 2 ft), but the worksheet refuses it on Calculate until it is 1 ft or less.
  • The search for “both targets are met” looks along the plotted variable only, with the others held. If the targets cannot be reached that way, the window says so; change another variable, or the targets.

Applicant’s Handbook reference

Appendix O, Dry Retention Systems: the removal tables go from 0.25 to 4.00 in of retention; BMPFast gives no more removal above 4 in.

Source reference

BMPFast method (frmSizing): the plot of removal against one variable and the search for the value that meets both targets are BMPFast’s; the removal at each value is the BMP’s own calculation.

Example: a retention basin

Example Problem 3 has one 11 ac catchment in Zone 4 (Non-DCIA CN 65, DCIA 25 %) with a target of 75 % for N and P. Its retention basin holds 0.506 ac-ft, a Treatment Depth of 0.552 in, and removes 75.0 %: it just meets the targets. In Sizing, with Retention Volume plotted, BMPFast gives:

Targets (N and P)Retention Volume that meets them
75 %0.506 ac-ft (the current design)
80 %0.646 ac-ft
85 %0.862 ac-ft
90 %1.229 ac-ft

Past about 4 ac-ft (4 in over the 11 ac) the curve is flat at 98.5 %: the retention curves stop at 4 in.

Surface Discharge Filter Sizing

A surface discharge filter treats the water an upstream BMP discharges: the overflow that is not retained. This window finds the smallest filter surface area that, with the upstream BMP, meets both targets. Open it with the Sizing button on the Surface Discharge Filter worksheet, or from Tools ▸ Surface Discharge Filter Sizing. The menu at the top switches catchment (leaving a catchment without Apply discards its sizing) and has a reset to the values the window opened with.

  1. Choose the Upstream BMP: any retention-type BMP or wet detention entered for this catchment, or None (catchment runoff to filter). The line under it shows the upstream removal and how much of the catchment it discharges to the filter. The Upstream BMP is a BMP in this catchment; runoff routed in from other catchments is not included, and the note under the results names those catchments.
  2. Choose the Filter media. Its treatment rate (gpm/sf, safety factor included) is shown beside it.
  3. Check the targets (as in Sizing). The Filter Surface Area (sf) box starts at the area that meets both targets.
  4. Read the Treatment Depth, the filter’s own removal, and the Total removal (upstream + filter). Type or step a larger area if you want a margin; Use goes back to the area that meets the targets.
  5. Apply writes the treatment depth and media to the filter and records the surface area for its report. Cancel restores the filter.

How it calculates (the same equations as the filter’s Equations page):

Area Discharging to Filter (ac) = Catchment Area (ac) x (100 - Upstream Hydraulic Capture (%)) / 100
Treatment Depth (in) = Filter Surface Area (sf) x Rate (gpm/sf) / (18.85 x Area Discharging to Filter (ac))
Filter N removal (%) = Capture at that depth x Media N reduction / 100      (P the same)
Total N removal (%)  = Upstream N + Filter N x (100 - Upstream N) / 100     (P the same)

18.85 is the filter area, in square feet, that treats one inch of runoff from one acre in a day at 1 gpm/sf: one inch over an acre is 43,560 / 12 = 3,630 cubic feet, and 1 gpm for a day is 0.0022288 x 86,400 = 192.6 cubic feet, so 3,630 / 192.6 = 18.85. A wet detention upstream retains no water, so all of the catchment discharges to the filter; with a wet detention upstream the media’s reduction for short residence times is used. The area found is the minimum; a larger filter is acceptable. The retention curves stop at 4 in, so if even a 4 in treatment depth cannot reach both targets the window says “Filter Surface Area cannot meet treatment requirements” and Apply is turned off.

Applicant’s Handbook reference

Appendix O, Detention with Engineered Media and Filtration: “Treatment efficiency for Detention Pond with Filtration = (Detention efficiency for Volume of the water Detained in the system) + (Volume of water filtered and not detained * Treatment Efficiency of Media)”; BMPFast’s total removal has this form, with the upstream BMP’s removal first and the filter’s capture times the media reduction applied to what it passes on.

Section 9.5.1 Treatment Train Nutrient Reduction (Equation 9-5): the upstream BMP and the filter are combined as a treatment train, 1 − [(1 − Eff1) × (1 − Eff2)].

Source reference

BMPFast method (Surface Discharge Filter Sizing, frmFilterSizing; upstream wet pond treated as under 2 hours, Ron, 2026-10-01): 18.85 is a unit conversion (one inch over one acre, 3,630 cf, divided by one day at 1 gpm, 192.57 cf); the area found is the minimum for that Treatment Depth, and there is no credit for an undersized filter.

Example. In Example Problem 3 the Retention basin captures 75.0 % of the runoff, so 2.749 of the 11 ac discharges to the filter. With B&G CTS12 media (0.052 gpm/sf) and targets of 85 % N and 90 % P, BMPFast finds 408 sf: Treatment Depth = 408 x 0.052 / (18.85 x 2.749) = 0.410 in. The filter removes 40.0 % N and 60.0 % P of what reaches it, and the total is 85.0 % N and 90.0 % P. Targets of 90 % N and 95 % P cannot be met with this media and basin.

Notes

  • Sizing works on the BMP itself while it is open: the worksheet shows the new values after Apply, and Cancel puts every value back.
  • How each BMP turns its dimensions into a Treatment Depth is on Retention BMPs; the retention curves are on Retention Methodology; the wet detention method is on Wet Detention Methodology.
  • A sized BMP that also receives runoff from other catchments treats more water in the project than here. Check the project result in the Summary Report or with Discovery Plots.

Sample problems

Worked problems solved in BMPFast, each with every input, the steps with screen captures, the program’s results, a hand check and the project file to download. Captures are for demonstration only. All of them: BMPFast sample problems.

Help home · List of every help page · This page on bmpfast.com · Sample problems